CANLI
Yükleniyor Veriler getiriliyor…
Scopus Özgün Makale Scopus
A comparative randomized trial of intubation success in difficult intubation cases: the use of a Frova intubation catheter versus a Bonfils intubation fiberoscope
Videosurgery and Other Miniinvasive Techniques 2019 Cilt 14 Sayı 4
Scopus Eşleşmesi Bulundu
5
Atıf
14
Cilt
486-494
Sayfa
🔓
Açık Erişim
Scopus Yazarları: Faruk Cicekci, Irem Gumus, Aysun Ozdemirkan, Mehmet Sari, Hasan Huseyin Bayram, Cansu Ciftci, Emine Aslanlar, Jale Çelik, Ozkan Onal
Özet
Introduction: A difficult airway is one of the main causes of morbidity and mortality in patients who undergo surgical interventions. Therefore, many devices and algorithms have been developed for the management of a difficult airway. However no study has been conducted comparing Frova catheter (FC) and a Bonfils fiberoscope (BF) to date. Aim: To compare the effectiveness and success of two devices, a FC and BF, in difficult intubation cases. Material and methods: Design: Single-centre randomized controlled trial in patients with difficult airways. The assignment order was created by unplanned number charts, and the assignment was hidden in closed covers, which were not unlocked until case permission had been provided. Setting: The trial was undertaken in a university hospital in Turkey. The primary analysis was based on 60 participants (n = 30, n = 30) with difficult intubation. The main outcomes were the success rates of placement of the tracheal tube in the trachea and the duration of the tracheal intubation process. Results: In the BF group, successful intubation was carried out in 25 of the 30 (83.3%) patients, whereas intubation was successful in 28 of the 30 patients (93.3%) in the FC group. Patients who could not be intubated with the first device were intubated with the other device. The mean duration of intubation was 109 (85–140) s in the BF group, whereas it was 38.8 (26–60) s in the FC group. Conclusions: Both devices were successful in difficult intubation cases. However, given the shorter duration of intubation using the FC and its lower cost as compared with that of the BF, the FC can be considered superior to the BF in difficult intubation cases.
Anahtar Kelimeler (Scopus)
Bonfils Catheters Difficult airway Endoscopes Equipment and supplies Frova Intratracheal Intubation

Anahtar Kelimeler

DİFFİCULT INTUBATION Bonfils Catheters Difficult airway Endoscopes Equipment and supplies Frova Intratracheal Intubation
mavi = YÖKSİS   yeşil = Scopus

Makale Bilgileri

Dergi Videosurgery and Other Miniinvasive Techniques
ISSN 1895-4588
Yıl 2019 / 1. ay
Cilt / Sayı 14 / 4
Sayfalar 486 – 494
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks Scopus
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 9 kişi
Erişim Türü Basılı
Alan Sağlık Bilimleri Temel Alanı Anesteziyoloji ve Reanimasyon DİFFİCULT INTUBATION

YÖKSİS Yazar Kaydı

Yazar Adı ÖNAL İBRAHİM ÖZKAN, GÜMÜŞ ÖZCAN İREM, ÖZDEMİRKAN Aysun, ÇİÇEKCİ FARUK, sarı mehmet, BAYRAM HASAN HÜSEYİN, ÇİFTÇİ CANSU, ASLANLAR EMİNE, ÇELİK JALE BENGİ
YÖKSİS ID 7453801