Comparison of the intubation success rate between the intubating catheter and videolaryngoscope in difficult airways: a prospective randomized trial
Brazilian Journal of Anesthesiology 2022 Cilt 72
Scopus Eşleşmesi Bulundu
6
Atıf
72
Cilt
55-62
Sayfa
🔓
Açık Erişim
Scopus Yazarları: Ali Ozgul Saltali, Mehmet Sari, Hasan Huseyin Bayram, Aysun Ozdemirkan, Ozkan Onal, Irem Ozcan, Emine Aslanlar, Cansu Ciftci
Özet
Background: Several devices and algorithms have already been examined and compared for difficult airway management. However, there is no existing study comparing the success of the Intubating Catheter (IC) and the Videolaryngoscope (VL) in patients who are difficult to intubate. We aimed to compare Frova IC and McGrath VL in terms of intubation success rates in patients with difficult intubation. Methods: This prospective, randomized study was performed in an university hospital. Patients who underwent an operation under general anesthesia and whom airway management process was deemed difficult were included in this study. Patients were randomly divided into two groups by envelopes containing a number: the intubating catheter group (Group IC), intubated using the Frova IC, and the videolaryngoscope group (Group VL), intubated using the McGrath VL. Study data were collected by a technician who was blind to the study groups and the type of device used in the intubation procedure. Results: A total of 49 patients with difficult airway were included in the study, including 25 patients in the Frova IC Group and 24 patients in the McGrath VL Group. The rate of successful intubation was determined to be 88% in Group IC and 66% in Group VL (p = 0.074). The mean duration of intubation attempt in Group VL was 44.62 seconds, whereas in Group IC, it was 51.12 seconds (p = 0.593). Group VL was found to have a significantly lower Cormack-Lehane grade compared to Group IC (p < 0.001). Conclusion: Frova IC is a candidate to be an indispensable instrument in terms of cost-effectiveness in clinics such as anesthesia and emergency medicine, where difficult intubation cases are frequently encountered. However, the combination of Frova IC and McGrath VL seems to be more successful in difficult intubation situations, so future studies should focus on using these two devices together.
Anahtar Kelimeler (Scopus)
Intratracheal Intubation Airway management Catheters Equipment and supplies

Anahtar Kelimeler

DİFFİCULT İNTUBATİON Intratracheal Intubation Airway management Catheters Equipment and supplies
mavi = YÖKSİS   yeşil = Scopus

Makale Bilgileri

Dergi Brazilian Journal of Anesthesiology
ISSN 0104-0014
Yıl 2022 / 1. ay
Cilt / Sayı 72
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q4
TEŞV Puanı 563,00
Yayın Dili Türkçe
Kapsam Uluslararası
Toplam Yazar 8 kişi
Erişim Türü Basılı+Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı Anesteziyoloji ve Reanimasyon DİFFİCULT İNTUBATİON

YÖKSİS Yazar Kaydı

Yazar Adı ÖZDEMİRKAN Aysun, ÖNAL İBRAHİM ÖZKAN, GÜMÜŞ ÖZCAN İREM, ASLANLAR EMİNE, SALTALI ALİ ÖZGÜL, sarı mehmet, ÇİFTÇİ CANSU, BAYRAM HASAN HÜSEYİN
YÖKSİS ID 7453799

Metrikler

Scopus Atıf 6
JCR Quartile Q4
TEŞV Puanı 563,00
Yazar Sayısı 8