SCI-Expanded
Özgün Makale
Scopus
Diagnostic efficacy of diffusion weighted MRI for pre operative assessment of myometrial and cervical invasion and pelvic lymph node metastasis in endometrial carcinoma
Journal of Medical Imaging and Radiation Oncology
2014
Cilt 58
Sayı 5
Scopus Eşleşmesi Bulundu
31
Atıf
58
Cilt
538-546
Sayfa
Scopus Yazarları: Hasan Erdogan, Mesut Sivri, Cengiz Erol, Alaaddin Nayman, Pınar Karabağlı, Y. Paksoy, M. Koplay, N. U. Doğan, Çetin Çelik
Özet
Introduction: To determine the diagnostic accuracy of diffusion-weighted magnetic resonance imaging (DW-MRI) for the pre-operative assessment of patients with endometrial carcinoma and to assess myometrial and cervical invasion as well as pelvic lymph node metastasis. Methods: Fifty-eight women who underwent surgery for histopathologically confirmed endometrial carcinoma were included in the current study. Prior to surgery, patients were evaluated using pelvic DW-MRI and gadolinium-enhanced T1-weighted imaging (Gd-T1WI). Gd-T1WI was evaluated together with T2-weighted images. DW-MR images were obtained in the axial plane using echo-planar spin-echo pulse sequences with different b factors. Endometrial carcinomas were observed as areas of increased intensity on DW-MRI images, and their intensity was compared with the surrounding hypo-intense myometrium. Pre-operative DW-MRI and Gd-T1WI results were compared with post-operative histopathological findings that served as reference standards. Results: The sensitivity, specificity, positive (PPV) and negative predictive values (NPV), and diagnostic accuracy of DW-MRI for differentiation between superficial myometrial invasion and deep myometrial invasion were 85%, 89%, 81%, 92% and 88%, respectively. The sensitivity, specificity and diagnostic accuracy rates were 82%, 91% and 89.6% for cervical invasion and 100%, 96% and 96.5% for pelvic lymph node metastasis, respectively. The sensitivity, specificity, PPV and NPV, and diagnostic accuracy of Gd-T1WI for differentiation between superficial myometrial invasion and deep myometrial invasion were 85%, 81.5%, 71%, 91% and 83%, respectively. The sensitivity, specificity and diagnostic accuracy were 73%, 89% and 86% for cervical invasion, respectively. Conclusions: These findings suggest that DW-MRI may be a good diagnostic tool with high sensitivity and specificity for assessing myometrial invasion and detecting tumour extension. We suggest that DW-MRI should be considered as a routine part of the pre-operative pelvic MRI in all patients with endometrial carcinoma.
Anahtar Kelimeler (Scopus)
Staging
Diffusion-weighted imaging
Endometrial carcinoma
MRI
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2014 yılı verileri
Journal of Medical Imaging and Radiation Oncology
Q2
SJR Quartile
0,485
SJR Skoru
54
H-Index
Kategoriler: Radiology, Nuclear Medicine and Imaging (Q2) · Oncology (Q3)
Alanlar: Medicine
Ülke: Australia
· Wiley-Blackwell Publishing Ltd
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
Staging
Diffusion-weighted imaging
Endometrial carcinoma
MRI
Makale Bilgileri
Dergi
Journal of Medical Imaging and Radiation Oncology
ISSN
17549477
Yıl
2014
/ 10. ay
Cilt / Sayı
58
/ 5
Sayfalar
538 – 546
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
8 kişi
Erişim Türü
Elektronik
Erişim Linki
Makaleye Git
Alan
Sağlık Bilimleri Temel Alanı-
Radyoloji
YÖKSİS Yazar Kaydı
Yazar Adı
KOPLAY MUSTAFA,DOĞAN NASUH UTKU,ERDOĞAN HASAN,SİVRİ MESUT,EROL CENGİZ,NAYMAN ALAADDİN,KARABAĞLI PINAR,PAKSOY YAHYA
YÖKSİS ID
915948
Hızlı Erişim
Metrikler
Scopus Atıf
31
Yazar Sayısı
8