CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
A comparison between two different automated total 25 hydroxyvitamin D immunoassay methods using liquid chromatography tandem mass spectrometry
Biochemia Medica 2015 Cilt 25 Sayı 3
Scopus Eşleşmesi Bulundu
22
Atıf
25
Cilt
430-438
Sayfa
🔓
Açık Erişim
Scopus Yazarları: Fatma Emel Kocak, Bahadır Öztürk, Ozben Ozden Isiklar, Ozlem Genc, Ali Ünlü, Irfan Altuntas
Özet
Introduction: Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatographytandem mass spectrometry (LC-MS/MS). Materials and methods: One hundred venous blood samples were randomly selected from routine vitamin D tests. Two of the serum aliquots were analyzed at the Abbott Architect i2000 and the Roche Cobas 6000’s module e601 in our laboratory within the same day. The other serum aliquots were analyzed at the LC-MS/MS in different laboratory. Passing-Bablok regression analysis and Bland-Altman plot were used to compare methods. Inter-rater agreement was analyzed using kappa (κ) analysis. Results: The Roche assay showed acceptable agreement with the LC-MS/MS based on Passing-Bablok analysis (intercept: -5.23 nmol/L, 95% CI: -8.73 to 0.19; slope: 0.97, 95% CI: 0.77 to 1.15). The Abbott assay showed proportional (slope: 0.77, 95% CI: 0.67 to 0.85) and constant differences (intercept: 17.08 nmol/L; 95% CI: 12.98 to 21.39). A mean bias of 15.1% was observed for the Abbott and a mean bias of -14.1% was observed for the Roche based on the Bland-Altman plots. We found strong to nearly perfect agreement in vitamin D status between the immunoassays and LC-MS/ MS. (κ: 0.83 for Abbott, κ: 0.93 for Roche) using kappa analysis. Conclusion: Both immunoassays demonstrated acceptable performance, but the Roche Cobas assay demonstrated better performance than the Abbott Architect in the studied samples.
Anahtar Kelimeler (Scopus)
25-Hydroxyvitamin D Tandem mass spectrometry Chromatography Immunoassay Methods
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2015 yılı verileri
Biochemia Medica
Q2
SJR Quartile
0,718
SJR Skoru
56
H-Index
🔓
Açık Erişim
Kategoriler: Biochemistry (medical) (Q2) · Clinical Biochemistry (Q2)
Alanlar: Biochemistry, Genetics and Molecular Biology · Medicine
Ülke: Croatia · Biochemia Medica, Editorial Office
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

25-Hydroxyvitamin D Tandem mass spectrometry Chromatography Immunoassay Methods

Makale Bilgileri

Dergi Biochemia Medica
ISSN 1330-0962
Yıl 2015 / 1. ay
Cilt / Sayı 25 / 3
Sayfalar 430 – 438
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
TEŞV Puanı 135,00
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 6 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı- Tıbbi Biyokimya

YÖKSİS Yazar Kaydı

Yazar Adı Fatma Emel Kocak,ÖZTÜRK BAHADIR,Ozben Ozden Isiklar,Ozlem Genc,Unlu Ali,Irfan Altuntas
YÖKSİS ID 247309

Metrikler

Scopus Atıf 22
TEŞV Puanı 135,00
Yazar Sayısı 6