CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus 🔓 Açık Erişim YÖKSİS Eşleşti

Effect of preload and heart rate on the Doppler and tissue Doppler-derived myocardial performance index

Clinical Cardiology · Temmuz 2007

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Effect of Preload and Heart Rate on the Doppler and Tissue Doppler derived Myocardial Performance Index
Clinical Cardiology · 2007 SCI-Expanded
PROFESÖR BÜLENT BEHLÜL ALTUNKESER →
Effect of Preload and Heart Rate on the Doppler and Tissue Doppler-derived Myocardial Performance Index
Clinical Cardiology · 2007 SCI-Expanded
PROFESÖR LÜTFULLAH ALTINTEPE →
Effect of Preload and Heart Rate on the Doppler and Tissue Doppler-derived Myocardial Performance Index
Clinical Cardiology · 2007 SCI
PROFESÖR NAZİF AYGÜL →

Makale Bilgileri

DergiClinical Cardiology
Yayın TarihiTemmuz 2007
Cilt / Sayfa30 · 342-348
Erişim🔓 Açık Erişim
Özet Doppler-derived myocardial performance index (MPI) has been described as a noninvasive measurement of LV function. Our aim was to investigate the effect of hemodialysis related volume reduction and heart rate changes on the Doppler-derived LV MPI, and Doppler tissue imaging (DTI) derived left and right ventricular MPI. Method: The study group comprised 32 consecutive patients (mean age: 43 ± 18 yrs) undergoing hemodialysis. Patients underwent echocardiography before and immediately after hemodialysis session. Left and right ventricular MPI derived from conventional pulsed-wave Doppler and DTI was calculated. The difference in MPI, heart rate and body weight was calculated before and after hemodialysis. Results: Doppler-derived LV MPI, and right ventricular MPI obtained by DTI were increased (p = 0.05) but the LV MPI obtained by DTI was unchanged after hemodialysis. There is a significant positive correlation between the Doppler-derived LV MPI difference and volume reduction (r = 0.38, p = 0.032). The heart rate difference was correlated with Doppler-derived LV MPI difference, and DTI derived right ventricular MPI difference (r = 0.38, p = 0.034; r = 0.48, p = 0.006, respectively). Whereas, DTI derived LV MPI difference was not correlated with heart rate difference. By the multivariate analysis, there was no correlation between Doppler-derived LV MPI difference with heart rate difference, and volume reduction. Right ventricular MPI difference correlated with heart rate difference (r = 0.41, p = 0.021) but not with volume reduction. Doppler-derived MPI is partially influenced by preload and heart rate changes. However, DTI derived LV MPI is not influenced by preload and heart rate changes. © 2007 Wiley Periodicals, Inc.

Yazarlar (9)

1
Kurtuluş Özdemir
2
Sibel Balci
3
Mehmet Akif Düzenli
4
Ilknur Can
5
Mehmet Yazici
6
Nazif Aygül
7
Bulent Behlul Altunkeser
8
Lütfullah Altıntepe
9
Suleyman Turk

Anahtar Kelimeler

Doppler tissue imaging Heart rate changes Myocardial performance index Volume reduction

Kurumlar

Selçuk Üniversitesi
Selçuklu Turkey

Metrikler

32
Atıf
9
Yazar
4
Anahtar Kelime

Sistemimizdeki Yazarlar