CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS Eşleşti

Electrochemical modification of glassy carbon electrode by poly-4-nitroaniline and its application for determination of copper(II)

Electrochimica Acta · Ekim 2010

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Electrochemical modification of glassy carbon electrode by poly 4 nitroaniline and its application for determination of copper II
Electrochimica Acta · 2010 SCI
DOKTOR ÖĞRETİM ÜYESİ TUĞÇE GÖVER →
Electrochemical modification of glassy carbon electrode by poly 4 nitroaniline and its application for determination of copper II
Electrochimica Acta · 2010 SSCI
PROFESÖR ZAFER YAZICIGİL →
Electrochemical modification of glassy carbon electrode by poly 4 nitroaniline and its application for determination of copper II
Electrochimica Acta · 2010 SCI-Expanded
PROFESÖR YASEMİN ÖZTEKİN →

Makale Bilgileri

DergiElectrochimica Acta
Yayın TarihiEkim 2010
Cilt / Sayfa56 · 387-395
Özet Electrochemical modification of glassy carbon (GC) electrode by poly-4-nitroaniline (P4NA), electrochemical reduction of P4NA and applicability of electrode modified in this way for determination of copper(II) (Cu(II)) is reported in this study. Electrochemical surface modification was performed by cyclic voltammetry in the potential range between +0.9 V and +1.4 V vs. Ag/Ag+ (in 10 mM AgNO3) at the scan rate of 100 mV/s by 100 cycles in non-aqueous media. In order to provide electrochemical reduction of nitro groups on the P4NA-modified GC electrode surface (P4NA/GC), the cyclic voltammograms inducing/evidencing the reduction of nitro groups were performed in the potential range between -0.1 V and -0.8 V vs. Ag/AgCl/(sat.KCl) at the scan rate of 100 mV/s. The reduced P4NA/GC surfaces (Reduced-P4NA/GC) were treated with aqueous solution of nitrilotriacetic acid. The sensitivity of GC electrode modified in described way towards Cu(II) was investigated in Britton-Robinson buffer solution, pH 5.0. The potentiometric generic pulse technique was applied as innovative electrochemical method for detection of analytical signal. It was shown that GC electrodes modified in here described way will be suitable for the determination of Cu(II) in technological waste water and/or some other solutions containing Cu(II) ions. © 2010 Elsevier Ltd.

Yazarlar (8)

1
Yasemin Oztekin
2
Mutahire Tok
3
Hande Nalvuran
4
Saliha Kiyak
5
Tuğçe Göver
6
Zafer Yazicigil
7
Almira Ramanaviciene
8
Arunas Ramanavicius

Anahtar Kelimeler

4-Nitroaniline Conducting polymers Electrochemically generated polymers Electrochemical polymerization Glassy carbon electrode Surface modification

Kurumlar

Ankara Üniversitesi
Ankara Turkey
Fizinių ir Technologijos Mokslų Centras
Vilnius Lithuania
Selçuk Üniversitesi
Selçuklu Turkey
Vilniaus Universitetas
Vilnius Lithuania

Metrikler

45
Atıf
8
Yazar
6
Anahtar Kelime