CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS DOI Eşleşti SJR Q1

Elution of monomer from different bulk fill dental composite resins

Dental Materials · Ocak 2015

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Elution of monomer from different bulk fill dental composite resins
Dental Materials · 2015 SSCI 3 atıf
Prof. Dr. ALİ RIZA ÇETİN →
YÖKSİS ISSN Eşleşmesi

Bu dergide (ISSN eşleşmesi) kurumun 3 kaydı bulundu.

YÖKSİS Kayıtları — ISSN Eşleşmesi
Effect of water storage on stress distribution in root filled premolars
2015 ISSN: 01095641 SCI-Expanded
Prof. Dr. OĞUZ ERASLAN →
Elution of monomer from different bulk fill dental composite resins
2015 ISSN: 01095641 SSCI 3 atıf
Prof. Dr. ALİ RIZA ÇETİN →
Effect of water storage on stress distribution in root filled premolars
2015 ISSN: 01095641 SCI-Expanded
Prof. Dr. SEMA BELLİ →

Makale Bilgileri

ISSN01095641
Yayın TarihiOcak 2015
Cilt / Sayfa31 · e141-e149
Özet Objective The purpose of this study was to evaluate the elution of Bis-GMA, TEGDMA, HEMA, and Bis-EMA monomers from six bulk fill composite resins over four different time periods, using HPLC. Methods Six different composite resin materials were used in the present study: Tetric Evo Ceram Bulk Fill (Ivoclar Vivadent, Amherst, NY), X-tra Fill (VOCO, Cuxhaven, Germany), Sonic Fill (Kerr, Orange, CA, USA), Filtek Bulk Fill (3M ESPE Dental Product, St. Paul, MN), SDR (Dentsply, Konstanz, Germany), EQUIA (GC America INC, Alsip, IL). The samples (4 mm thickness, 5 mm diameter) were prepared and polymerized for 20 s with a light emitted diode unit. After fabrication, each sample was immediately immersed in 75 wt% ethanol/water solution used as extraction fluid and stored in the amber colored bottles at room temperature. Ethanol/water samples were taken (0.5 mL) at predefined time intervals:10 m (T1), 1 h (T2), 24 h (T3) and 30 days (T4). These samples were analyzed by HPLC. The obtained data were analyzed with one-way ANOVA and Tukey HSD at significance level of p < 0.05. Results Amount of eluted Bis-EMA and Bis-GMA from Tetric Evo Ceram Bulk Fill and amount of eluted TEGDMA and HEMA from X-tra Fill higher than others composites (p < 0.05). Significance Residual monomers were eluted from bulk fill composite resins in all time periods and the amount of eluted monomers was increased with time.

Yazarlar (6)

1
Mehmet Ata Cebe
2
Fatma Cebe
3
Mehmet Fatih Cengiz
4
Ali Riza Cetin
5
Osman Fatih Arpag
6
Bora Ozturk

Anahtar Kelimeler

Bulk fill composite resin Elution HPLC Residual monomer

Kurumlar

Akdeniz Üniversitesi
Antalya Turkey
Bolu Abant İzzet Baysal Üniversitesi
Bolu Turkey
Mustafa Kemal Üniversitesi
Antakya Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Scimago Dergi (ISSN Eşleşmesi)
Dental Materials
Q1
SJR Skoru1,524
H-Index187
YayıncıElsevier Inc.
ÜlkeUnited States
Dentistry (miscellaneous) (Q1)
Materials Science (miscellaneous) (Q1)
Mechanics of Materials (Q1)
Dergi sayfasına git

Metrikler

98
Atıf
6
Yazar
4
Anahtar Kelime

Sistemimizdeki Yazarlar