Scopus
🔓 Açık Erişim YÖKSİS DOI Eşleşti
SJR Q1
Conventional and high intensity halogen light effects on water sorption and microhardness of orthodontic adhesives
Angle Orthodontist · Ocak 2008
YÖKSİS Kayıtları
Conventional and High Intensity Halogen Light Effects on Water Sorption and Microhardness of Orthodontic Adhesives
The Angle Orthodontist · 2008 SCI-Expanded 7 atıf
Prof. Dr. MURAT SELİM BOTSALI →
Conventional and High Intensity Halogen Light Effects on Water Sorption and Microhardness of Orthodontic Adhesives
The Angle Orthodontist · 2008 SCI-Expanded
Prof. Dr. MURAT SELİM BOTSALI →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Asymmetric rapid maxillary expansion in true unilateral crossbite malocclusion A prospective controlled clinical study i
2015 ISSN: 0003-3219 SCI
Prof. Dr. ZEHRA İLERİ →
Alveolar bone changes after asymmetric rapid maxillary expansion
2015 ISSN: 0003-3219 SCI
Prof. Dr. ZEHRA İLERİ →
Alveolar bone changes after asymmetric rapid maxillary expansion
2015 ISSN: 0003-3219 SCI-Expanded
Prof. Dr. ZELİHA MÜGE BAKA →
Microscopic evaluation of mandibular symphyseal distraction osteogenesis
2006 ISSN: 0003-3219 SCI-Expanded 4 atıf
Prof. Dr. HASAN KÜÇÜKKOLBAŞI →
Does the timing and method of rapid maxillary expansion have an effect on the changes in nasal dimensions
2016 ISSN: 0003-3219 SCI-Expanded 65 atıf
Prof. Dr. HASAN KÜÇÜKKOLBAŞI →
Conventional and High Intensity Halogen Light Effects on Water Sorption and Microhardness of Orthodontic Adhesives
2008 ISSN: 0003-3219 SCI-Expanded 7 atıf Q3
Prof. Dr. MURAT SELİM BOTSALI →
Effects of remineralization procedures on shear bond strengths of brackets bonded to demineralized enamel surfaces with self etch systems
2016 ISSN: 0003-3219 SCI-Expanded
Prof. Dr. ZELİHA MÜGE BAKA →
Conventional and High Intensity Halogen Light Effects on Water Sorption and Microhardness of Orthodontic Adhesives
2008 ISSN: 0003-3219 SCI-Expanded
Prof. Dr. MURAT SELİM BOTSALI →
Effects of remineralization procedures on shear bond strengths of brackets bonded to demineralized enamel surfaces with self etch systems
2016 ISSN: 0003-3219 SCI
Prof. Dr. ZEHRA İLERİ →
Three dimensional evaluation of hybrid expander appliances A pilot study
2016 ISSN: 0003-3219 SCI
Prof. Dr. ZEHRA İLERİ →
Cytotoxic effects of orthodontic composites
2010 ISSN: 0003-3219 SCI-Expanded
Prof. Dr. HAYRİYE ESRA ÜLKER →
Cytotoxic effects of resin modified orthodontic band adhesives Are they safe
2010 ISSN: 0003-3219 SCI-Expanded
Prof. Dr. HAYRİYE ESRA ÜLKER →
Intraosseous screw-supported upper molar distalization
2004 ISSN: 0003-3219 SCI-Expanded Q3
Prof. Dr. ABDULLAH KALAYCI →
Effect of injectable platelet-rich fibrin (i-PRF) on the rate of tooth movement: A randomized clinical trial
2021 ISSN: 0003-3219 SCI-Expanded Q3
Prof. Dr. SEMA HAKKI →
Three-dimensional soft tissue evaluation after rapid maxillary expansion and mandibular midline distraction osteogenesis
2021 ISSN: 0003-3219 SCI
Prof. Dr. ZEHRA İLERİ →
Makale Bilgileri
Dergi
Angle Orthodontist
ISSN00033219
Yayın TarihiOcak 2008
Cilt / Sayfa78 · 134-139
Scopus ID2-s2.0-38349003164
Erişim🔓 Açık Erişim
Özet
Objective: To test the null hypothesis that when the equivalent total light energy is irradiated to three orthodontic adhesive resins, there is no difference between the microhardness and water sorption values regardless of the curing light sources. Materials and Methods: Samples were divided into six groups according to the combination of three orthodontic adhesives (Kurasper F, Light-Bond, Transbond XT) and two light intensities (quartz tungsten halogen [QTH] and high intensity quartz tungsten halogen [HQTH]). One half of each of the 40 samples of three adhesive pastes was polymerized for 20 seconds by a QTH light source, and the other half was polymerized for 10 seconds by a HQTH light source. Water sorption was determined and Vickers hardness was established with three measurements per sample at the top, center, and bottom. Statistical analysis was performed using two-way analysis of variance (ANOVA) with multiple comparisons (Tukey-HSD). Results: Statistically significant differences were found among all adhesives for water sorption and hardness values cured with QTH and HQTH. The HQTH curing unit resulted in higher values than did the QTH. The highest water sorption values were observed for Kurasper F cured with HQTH and the lowest value was observed for Transbond XT cured with QTH. For microhardness Light-Bond cured with HQTH produced the highest values, and Transbond XT cured with QTH produced the lowest. Conclusions: When the equivalent total light energy is irradiated to three orthodontic adhesive resins, there are significant differences between the microhardness and water sorption values cured with the QTH and HQTH light source. The null hypothesis is rejected. © 2008 by The EH Angle Education and Research Foundation, Inc.
Yazarlar (5)
1
Tancan Uysal
2
Faruk Ayhan Basciftci
3
Y. Sener
4
Murat Selim Botsali
5
Abdullah Demir
Anahtar Kelimeler
Composites
Halogen
Vickers hardness
Water sorption
Kurumlar
Erciyes Üniversitesi
Kayseri Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Scimago Dergi (ISSN Eşleşmesi)
Angle Orthodontist
Q1
OA
SJR Skoru1,433
H-Index120
YayıncıAllen Press Inc.
ÜlkeUnited States
Medicine (miscellaneous) (Q1)
Orthodontics (Q1)
Metrikler
16
Atıf
5
Yazar
4
Anahtar Kelime