CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus 🔓 Açık Erişim YÖKSİS DOI Eşleşti SJR Q2

Evaluation of temperature changes in the pulp chamber during polymerization of light-cured pulp-capping materials by using a VALO LED light curing unit at different curing distances

Dental Materials Journal · Ocak 2014

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Evaluation of temperature changes in the pulp chamber during polymerization of light cured pulp capping materials by using a VALO LED light curing unit at different curing distances
Dental Materials Journal · 2014 SCI-Expanded
Prof. Dr. MURAT SELİM BOTSALI →
Evaluation of temperature changes in the pulp chamber during polymerization of light cured pulp capping materials by using a VALO LED light curing unit at different curing distances
Dental Materials Journal · 2014 SCI-Expanded
Prof. Dr. MURAT SELİM BOTSALI →
YÖKSİS ISSN Eşleşmesi

Bu dergide (ISSN eşleşmesi) kurumun 16 kaydı bulundu.

YÖKSİS Kayıtları — ISSN Eşleşmesi
Shear bond strength of orthodontic brackets to aged nano hybrid compositeresin surfaces using different surface preparation
2015 ISSN: 0287-4547 SCI-Expanded
Prof. Dr. ZEHRA İLERİ →
Cytotoxicity evaluation of luting resin cements on bovine dental pulp derived cells bDPCs by real time cell analysis
2015 ISSN: 0287-4547 SCI-Expanded
Prof. Dr. SEMA HAKKI →
Influence of powdered dentin on the shear bond strength of dentin bonding systems
2012 ISSN: 0287-4547 SCI-Expanded
Prof. Dr. SEMA BELLİ →
Cytotoxicity evaluation of luting resin cements on bovine dental pulp derived cells bDPCs by real time cell analysis
2015 ISSN: 0287-4547 SCI-Expanded
Prof. Dr. NECLA DEMİR →
Evaluation of temperature changes in the pulp chamber during polymerization of light cured pulp capping materials by using a VALO LED light curing unit at different curing distances
2014 ISSN: 0287-4547 SCI-Expanded
Prof. Dr. MURAT SELİM BOTSALI →
Antibacterial effect of chlorhexidine-cetrimide combination, <i>Salvia officinalis</i> plant extract and octenidine in comparison with conventional endodontic irrigants
2016 ISSN: 0287-4547 SCI-Expanded
Prof. Dr. AYÇE ÜNVERDİ →
Push-out bond strength of a new post system after various post space treatments
2016 ISSN: 0287-4547 SSCI
Prof. Dr. AYÇE ÜNVERDİ →
Treatment of post-orthodontic white spot lesions with CPP-ACP paste: A three year follow up study
2017 ISSN: 0287-4547 SCI-Expanded
Prof. Dr. NİMET ÜNLÜ →
Treatment of post-orthodontic white spot lesions with CPP-ACP paste: A three year follow up study
2017 ISSN: 0287-4547 SCI-Expanded
Prof. Dr. MURAT SELİM BOTSALI →
Effect of airborne particle abrasion and sintering order on the surface roughness and shear bond strength between Y-TZP ceramic and resin cement
2019 ISSN: 0287-4547 SCI-Expanded Q3
Prof. Dr. MÜNİR TOLGA YÜCEL →
Temperature rise under normal and caries-affected primary tooth dentin disks during polymerization of adhesives and resin-containing dental materials
2008 ISSN: 0287-4547 SCI-Expanded
Prof. Dr. GÜL TOSUN →
Evaluation of human pulp tissue response following direct pulp capping with a self-etching adhesive system containing MDPB
2021 ISSN: 0287-4547 SCI-Expanded Q3
Prof. Dr. NEVİN ÇOBANOĞLU →
Five-year clinical follow-up of bulk-fill restorative materials in class II restorations
2024 ISSN: 0287-4547 SCI-Expanded Q2
Doç. Dr. MERVE GÜRSES →
One-year clinical evaluation of direct nanofilled and indirect composite restorations in posterior teeth
2009 ISSN: 0287-4547 SCI Q4
Prof. Dr. ALİ RIZA ÇETİN →
Five-year clinical follow-up of bulk-fill restorative materials in class II restorations
2024 ISSN: 0287-4547 SSCI
Prof. Dr. NEVİN ÇOBANOĞLU →
Immediate and Delayed Repair Of Bulk-Fill Composite Resin
2024 ISSN: 0287-4547 SCI-Expanded
Prof. Dr. NEVİN ÇOBANOĞLU →

Makale Bilgileri

ISSN02874547
Yayın TarihiOcak 2014
Cilt / Sayfa33 · 764-769
Erişim🔓 Açık Erişim
Özet The aim of this study was to evaluate temperature changes in the pulp chamber during polymerization of four different pulpcapping materials using a LED-light-curing-unit in the contact and noncontact positions. A pulpal circulation mechanism was simulated to measure increases in temperature in four pulp-capping materials that were applied to the occlusal dentin surface. Two different distances were used between the tip of the unit and the material surface during polymerization; 0 and 2 mm. The data were statistically analyzed using factorial-ANOVA, one-way-ANOVA, and Tukey’s HSD test. There were statistically differences between contact and noncontact groups (p<0.05). Contact groups produced significantly lower temperature rise compared with noncontact groups. The highest and lowest mean temperature increases were calculated for the Biner LC and the TheraCal LC, respectively. Considering the effects of temperature rising, the distance of the light curing units from restorations should not be overlooked as well as the types of the materials.

Yazarlar (4)

1
S. Savas
2
Murat Selim Botsali
3
Ebru Küçükyilmaz
4
T. Sari

Anahtar Kelimeler

Light curing unit Pulp-capping materials Pulp chamber Temperature rise

Kurumlar

Bezmiâlem Vakıf Üniversitesi
Istanbul Turkey
İzmir Kâtip Çelebi Üniversitesi
Izmir Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Scimago Dergi (ISSN Eşleşmesi)
Dental Materials Journal
Q2
SJR Skoru0,567
H-Index74
YayıncıJapanese Society for Dental Materials and Devices
ÜlkeJapan
Ceramics and Composites (Q2)
Dentistry (miscellaneous) (Q2)
Dergi sayfasına git

Metrikler

49
Atıf
4
Yazar
4
Anahtar Kelime

Sistemimizdeki Yazarlar