Scopus
🔓 Açık Erişim YÖKSİS Eşleşti
Residual HEMA and TEGDMA release and cytotoxicity evaluation of resin-modified glass ionomer cement and compomers cured with different light sources
The Scientific World Journal · Ocak 2014
YÖKSİS Kayıtları
Residual HEMA and TEGDMA Release and Cytotoxicity Evaluation of Resin Modified Glass Ionomer Cement and Compomers Cured with Different Light Sources
The Scientific World Journal · 2014 SCI-Expanded
PROFESÖR HAYRİYE ESRA ÜLKER →
Residual HEMA and TEGDMA Release and Cytotoxicity Evaluation of Resin Modified Glass Ionomer Cement and Compomers Cured with Different Light Sources
The Scientific World Journal · 2014 EBSCO
PROFESÖR MURAT SELİM BOTSALI →
Residual HEMA and TEGDMA Release and Cytotoxicity Evaluation of Resin Modified Glass Ionomer Cement and Compomers Cured with Different Light Sources
The Scientific World Journal · 2014 SCI-Expanded
PROFESÖR MURAT SELİM BOTSALI →
Makale Bilgileri
DergiThe Scientific World Journal
Yayın TarihiOcak 2014
Cilt / Sayfa2014
Scopus ID2-s2.0-84896858598
Erişim🔓 Açık Erişim
Özet
The purpose of this study was first to evaluate the elution of 2-hydroxyethyl methacrylate (HEMA) and triethylene glycol dimethacrylate (TEGDMA) monomers from resin-modified glass ionomer cement (RMGIC) and compomers cured with halogen and light-emitting diode (LED) light-curing units (LCUs). The effect of cured materials on the viability of L929 fibroblast cells was also evaluated. One RMGIC (Ketac N100) and two compomers (Dyract Extra and Twinkystar) were tested. Materials were prepared in teflon disks and light-cured with LED or halogen LCUs. The residual monomers of resin materials in solution were identified using high-performance liquid chromatography. The fibroblast cells' viability was analyzed using MTT assay. The type of LCU did not have a significant effect on the elution of HEMA and TEGDMA. A greater amount of HEMA than TEGMDA was eluted. The amount of TEGDMA eluted from Twinkystar was greater than Dyract Extra (P < 0.05) when cured with a halogen LCU. All material-LCU combinations decreased the fibroblast cells' viability more than the control group (P < 0.01), except for Dyract Extra cured with a halogen LCU (P > 0.05). Curing with the LED LCU decreased the cells' viability more than curing with the halogen LCU for compomers. For Ketac N100, the halogen LCU decreased the cells' viability more than the LED LCU. © 2014 Murat Selim Botsali et al.
Yazarlar (8)
1
Murat Selim Botsali
2
Adem Kuşgöz
3
Subutay Han Altintaş
4
H. E. Ülker
5
Mehmet Tanriver
6
Serdar Kiliç
7
Feridun Başak
8
Mustafa Ulker
Kurumlar
Gülhane Eğitim ve Araştırma Hastanesi
Ankara Turkey
Karadeniz Technical University
Trabzon Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Şifa Üniversitesi
Izmir Turkey
Metrikler
17
Atıf
8
Yazar