CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus 🔓 Açık Erişim YÖKSİS Eşleşti

Evaluation of HEMA released from four different adhesive systems by HPLC

Journal of Applied Biomaterials and Functional Materials · Nisan 2015

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Evaluation of HEMA released from four different adhesive systems by HPLC
Journal of Applied Biomaterials & Functional Materials · 2015 SCI-Expanded
PROFESÖR MURAT SELİM BOTSALI →
Evaluation of HEMA released from four different adhesive systems by HPLC
Journal of Applied Biomaterials & Functional Materials · 2015 SCI-Expanded
PROFESÖR HAYRİYE ESRA ÜLKER →
Evaluation of HEMA released from four different adhesive systems by HPLC
Journal of Applied Biomaterials & Functional Materials · 2015 SCI-Expanded
PROFESÖR MURAT SELİM BOTSALI →

Makale Bilgileri

DergiJournal of Applied Biomaterials and Functional Materials
Yayın TarihiNisan 2015
Cilt / Sayfa13 · E100-E105
Erişim🔓 Açık Erişim
Özet Purpose: This study evaluated the elution of 2-hydroxyethyl methacrylate (HEMA) from 4 different adhesives, using highperformance liquid chromatography (HPLC). Materials and methods: The adhesives were applied on a bovine dentin surface and polymerized using an LED curing unit (n=5). After polymerization, specimens were stored in 75% ethanol solution (6 mL). Residual HEMA that was eluted from adhesives (after 10 minutes, 1 hour, 24 hours, 7 days and 30 days) was analyzed using HPLC. Statistical analyses were performed using 1-way ANOVA, Tukey HSD test and paired 2-sample t-test. Results: There were statistically significant differences among adhesive systems for the cumulative released HEMA and among the time periods (p<0.05). Clearfil SE Bond showed the highest amount of HEMA released, while Easy Bond showed the lowest. Among the time periods, the highest eluted HEMA value was detected in 10 minutes for all adhesives, and elution continued for up to 30 days. Conclusions: The HEMA eluted from adhesives was in different amounts, and the elution continued for a long time. The amount of eluted HEMA from adhesives used in this study was not viewed as critical for toxic reactions in biological tissues.

Yazarlar (3)

1
Mustafa Altunsoy
2
Murat Selim Botsali
3
H. E. Ülker

Anahtar Kelimeler

Adhesives Cytotoxicity HPLC Residual HEMA

Kurumlar

Necmettin Erbakan Üniversitesi
Meram Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Şifa Üniversitesi
Izmir Turkey

Metrikler

5
Atıf
3
Yazar
4
Anahtar Kelime

Sistemimizdeki Yazarlar