CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS DOI Eşleşti SJR Q2

Comparison of the mechanical and biological properties of self-adhering materials

Journal of Adhesion Science and Technology · Mayıs 2016

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Comparison of the mechanical and biological properties of self adhering materials
Journal of Adhesion Science and Technology · 2016 SCI-Expanded
Prof. Dr. HAYRİYE ESRA ÜLKER →
Comparison of the mechanical and biological properties of self-adhering materials
Journal of Adhesion Science and Technology · 2016 SCI-Expanded
Doç. Dr. FİRDEVS KAHVECİOĞLU →
YÖKSİS ISSN Eşleşmesi

Bu dergide (ISSN eşleşmesi) kurumun 20 kaydı bulundu.

YÖKSİS Kayıtları — ISSN Eşleşmesi
Are dentin posts biomechanically intensive A laboratory and FEA study
2014 ISSN: 0169-4243 SSCI
Prof. Dr. OĞUZ ERASLAN →
Does 2 chlorhexidine digluconate cavity disinfectant or sodium fluoride hydroxyethyl methacrylate affect adhesion of universal adhesive to dentin
2015 ISSN: 0169-4243 SSCI
Prof. Dr. ALİ RIZA ÇETİN →
Functionalization of polystyrene and adhesion studies
1997 ISSN: 0169-4243 SCI-Expanded 25 atıf
Prof. Dr. AHMET OKUDAN →
Effects of the functional groups of polystyrene on its adhesion improvement and corrosion resistance
1998 ISSN: 0169-4243 SCI-Expanded 23 atıf
Prof. Dr. AHMET OKUDAN →
Response of exposed human pulp to application of a hemostatic agent and a self etch adhesive
2015 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. ÖZGÜR ÖZDEMİR →
Adhesion and corrosion resistance properties of coatings obtained from modified low molecular weight polystyrenes
2006 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. AHMET KOÇAK →
Response of exposed human pulp to application of a hemostatic agent and a self etch adhesive
2015 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. NEVİN ÇOBANOĞLU →
POLYTETRAFLUOROETYLENE TAPE AS TEMPORARY RESTORATIVEMATERIAL A FLUID FILTRATION STUDY
2015 ISSN: 0169-4243 Endekste taranmıyor
Prof. Dr. SEMA BELLİ →
Which is effective on bond strength of resin based sealers incorporation of powdered dentin to primer or adhesive
2015 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. SEMA BELLİ →
Effect of 2 chlorhexidine gluconate cavity disinfectant on microtensile bond strength of tooth coloured restorative materials to sound and caries affected dentin
2015 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. SEMA BELLİ →
The effect of different restoration techniques on fracture strength of teeth with flared roots
2014 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. SEMA BELLİ →
Functionalization of polystyrene and adhesion studies
1997 ISSN: 0169-4243 SCI-Expanded 24 atıf
Prof. Dr. ERSİN GÜLER →
Effect of intracanal medicaments on the push out bond strength of Biodentine in comparison with Bioaggregate apical plugs
2015 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. AYÇE ÜNVERDİ →
Comparison of the mechanical and biological properties of self adhering materials
2016 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. HAYRİYE ESRA ÜLKER →
The effects of water flow rate on shear bond strength of self etch resin cement to dentin surface after Er,Cr:YSGG laser etching
2017 ISSN: 0169-4243 SCI
Prof. Dr. İSA YÖNDEM →
Comparison of the mechanical and biological properties of self-adhering materials
2016 ISSN: 0169-4243 SCI-Expanded Q3
Doç. Dr. FİRDEVS KAHVECİOĞLU →
Residual monomer release from orthodontic adhesives cured with different light sources
2016 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. MURAT SELİM BOTSALI →
Effect of post restoration on stresses in premolars with endodontic periodontal lesion an FEA study
2017 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. SEMA HAKKI →
Shear bond strength to enamel and failure type of different periodontal splints :in vivo and in vitro study
2016 ISSN: 0169-4243 SCI-Expanded Q3
Prof. Dr. NİMET ÜNLÜ →
The effects of water flow rate on shear bond strength of self etch resin cement to dentin surface after Er Cr YSGG laser etching
2016 ISSN: 0169-4243 SSCI
Prof. Dr. İSA YÖNDEM →

Makale Bilgileri

ISSN01694243
Yayın TarihiMayıs 2016
Cilt / Sayfa30 · 1119-1130
Özet Purpose: The purpose of the present study was to compare the Vickers hardness numbers (VHNs), roughness numbers (RNs) and biological compatibility of glass carbomer (Glass Fill), resin-modified glass ionomer (Fuji II LC) and self-adhering flowable composite (Vertise Flow) materials. Materials and methods: Disc-shaped specimens of test materials (n = 15/group) were prepared, and VHNs and RNs were determined after 24 h. A direct contact test was used for cytotoxicity evaluation. Cell viability was measured for 24 h post-exposition with a photometric test (MTT assay; n = 16). Data were analysed using one-way analysis of variance with a post hoc Tukeys test, the Kruskal-Wallis test and the Mann-Whitney U-test (p < 0.05). Results: Fuji II LC had the highest VHN. The VHN of Fuji II LC differed significantly from those of the other materials (p < 0.05). The RNs of Fuji II and Glass Fill were higher than that of Vertise Flow (p < 0.05). The self-adhering materials were not significantly cytotoxic compared with the control group (p > 0.05). Conclusions: The materials tested in this study showed a similar lack of cytotoxicity. The VHN of Fuji II LC was the highest, and the RN of Vertise Flow was the lowest.

Yazarlar (5)

1
H. E. Ülker
2
A. Erkan
3
Nuray Günaydin
4
Firdevs Kahvecioʇlu
5
Mustafa Ulker

Anahtar Kelimeler

Roughness and cytotoxicity Self-adhering materials Vickers microhardness

Kurumlar

Selçuk Üniversitesi
Selçuklu Turkey
Scimago Dergi (ISSN Eşleşmesi)
Journal of Adhesion Science and Technology
Q2
SJR Skoru0,548
H-Index92
YayıncıTaylor and Francis Ltd.
ÜlkeUnited Kingdom
Chemistry (miscellaneous) (Q2)
Materials Chemistry (Q2)
Mechanics of Materials (Q2)
Surfaces and Interfaces (Q2)
Surfaces, Coatings and Films (Q2)
Dergi sayfasına git

Metrikler

4
Atıf
5
Yazar
3
Anahtar Kelime

Sistemimizdeki Yazarlar