Scopus
YÖKSİS Eşleşti
Three-axis accelerometer system for comparison of gait parameters in children with cystic fibrosis and healthy peers
Gait and Posture · Mayıs 2020
YÖKSİS Kayıtları
Three-axis accelerometer system for comparison of gait parameters in children with cystic fibrosis and healthy peers
GAIT & POSTURE · 2020 SCI-Expanded
DOÇENT İSMAİL ÖZSOY →
Makale Bilgileri
DergiGait and Posture
Yayın TarihiMayıs 2020
Cilt / Sayfa78 · 60-64
Scopus ID2-s2.0-85082531353
Özet
Background: Cystic Fibrosis (CF), affecting functional exercise capacity generally measured by submaximal exercise test such as 6min walk test, is a progressive, autosomal recessive and metabolic disorder. Three-axis accelerometers, which are used during gait, are an easy way to assess gait parameters in patients and healthy individuals. Gait parameters were significantly associated with clinical outcomes of COPD. However, the association between gait parameters and clinical outcomes in children with CF is unclear. Research question: Do clinical outcomes in CF have an important role in determining gait parameters?. Methods: Twenty-one CF and 21 healthy subjects participated in this case-control study. Body composition was evaluated using Tanita-BC 418. Respiratory and knee extension muscle strengths were assessed. Functional exercise capacity was evaluated using the 6-min walk test (6MWT). Spatiotemporal gait parameters were evaluated using a validated wireless inertial sensing device (G-Sensor, BTS Bioengineering S.p.A., Italy) during the 6MWT and 7-meter gait test. Results: MIP, the distance of 6MWT, and stride length were significantly lower in the CF group compare to healthy children (p<0.05). Gait speed and functional exercise capacity, cadence and functional exercise capacity, quadriceps muscle strength, FEV1, fat-free mass were found to be correlated in CF patients (p<0.05). Significance: The aerobic capacity and gait parameters were affected in CF patients with mild disease severity in our study. Clinical outcomes were associated with gait parameters in CF patients. This is the first study to use the 3-axis accelerometer to evaluate functional exercise capacity and gait parameters of CF and healthy children. A three-axis accelerometer can be used to assess functional exercise capacity and gait parameters in CF patients at the clinics.
Yazarlar (9)
1
Ezgi Ergin
2
Sema Savci
3
Buse Ozcan Kahraman
4
Aylin Tanriverdi
ORCID: 0000-0002-0220-0642
5
İsmail Özsoy
6
Gizem Atakul
7
Ayşe Volkan
8
Suna Asilsoy
9
Nevin Uzuner
Anahtar Kelimeler
Accelerometer
Cystic fibrosis
Functional exercise capacity
Gait parameters
Six-minute walk distance
Kurumlar
Dokuz Eylül Üniversitesi
Izmir Turkey
Kırşehir Ahi Evran Üniversitesi
Kirsehir Turkey
Metrikler
4
Atıf
9
Yazar
5
Anahtar Kelime