Scopus
YÖKSİS DOI Eşleşti
SJR Q3
CANCER RISK ESTIMATION for PATIENTS UNDERGOING WHOLE-BODY PET/CT SCANS
Radiation Protection Dosimetry · Nisan 2023
YÖKSİS Kayıtları
Cancer risk estimation for patients undergoing whole-body PET/CT scans
Radiation Protection Dosimetry · 2023 SCI-Expanded
Prof. Dr. NİHAL BÜYÜKÇİZMECİ →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Determination of radon concentration levels in well water in Konya, Turkey
2013 ISSN: 0144-8420 SCI-Expanded
Prof. Dr. NURETDİN EREN →
Estimation of patient organ and whole-body doses in [18F-FDG] PET/CT scan
2023 ISSN: 0144-8420 SCI-Expanded Q4
Prof. Dr. NİHAL BÜYÜKÇİZMECİ →
Cancer risk estimation for patients undergoing whole-body PET/CT scans
2023 ISSN: 0144-8420 SCI-Expanded Q4
Prof. Dr. NİHAL BÜYÜKÇİZMECİ →
Gamma irradiation effect on some asthma drugs: EPR detection of radiosterilization
2023 ISSN: 0144-8420 SCI-Expanded Q4
Prof. Dr. ÜLKÜ AKPINAR →
EPR investigation of gamma-irradiated FAMOSER drug for DOSIMETRIC purposes
2023 ISSN: 0144-8420 SCI-Expanded Q4
Prof. Dr. ÜLKÜ AKPINAR →
Paramagnetic characterization of fossil mollusc shells at eastern part of the old Konya lake: its importance for EPR dating
2023 ISSN: 0144-8420 SCI-Expanded Q4
Prof. Dr. ÜLKÜ AKPINAR →
Makale Bilgileri
ISSN01448420
Yayın TarihiNisan 2023
Cilt / Sayfa199 · 509-518
Scopus ID2-s2.0-85152975876
Özet
The objective of this paper was to compute the effective dose, as well as the lifetime attributable risk (LAR) of cancer related to whole-body positron emission tomography (PET)/computed tomography (CT) scan for 193 adult patients. The mean effective dose for all patients from a single PET/CT scan was 20.6 mSv. For males aged 40 y, a single PET/CT scan is associated with a LAR of cancer incidence of 0.169%. This risk increased to 0.85% if an annual surveillance protocol for 5 y was performed. For female patients aged 40 y, the LAR of cancer mortality increased from 0.126 to 0.63% if an annual surveillance protocol for 5 y was performed. Since PET/CT scans are associated with a high dose and a risk of developing cancer, it was important to balance the advantages and risks before conducting any scans. This is especially important for younger patients and those who are overweight.
Yazarlar (3)
1
Aida Kessara
ORCID: 0000-0003-2479-7045
2
Nihal Buyukcizmeci
3
G. K. Gedik
Kurumlar
Selçuk Üniversitesi
Selçuklu Turkey
Scimago Dergi (ISSN Eşleşmesi)
Radiation Protection Dosimetry
Q3
SJR Skoru0,235
H-Index86
YayıncıOxford University Press
ÜlkeUnited Kingdom
Public Health, Environmental and Occupational Health (Q3)
Radiation (Q3)
Radiological and Ultrasound Technology (Q3)
Radiology, Nuclear Medicine and Imaging (Q3)
Medicine (miscellaneous) (Q4)
Metrikler
3
Atıf
3
Yazar