Scopus
🔓 Açık Erişim YÖKSİS DOI Eşleşti
SJR Q2
Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp
Biomed Research International · Ocak 2016
YÖKSİS Kayıtları
Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer Using Thermocure Lamp
BioMed Research International · 2016 SCI-Expanded
Prof. Dr. HAYRİYE ESRA ÜLKER →
Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer Using Thermocure Lamp
BioMed Research International · 2016 SCI-Expanded
Prof. Dr. GÜL TOSUN →
Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer„ Using Thermocure Lamp
Biomed Research International · 2016 SCI-Expanded
Doç. Dr. FİRDEVS KAHVECİOĞLU →
Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp
BioMed Research International · 2016 SCI-Expanded
Doç. Dr. FİRDEVS KAHVECİOĞLU →
YÖKSİS Kayıtları — ISSN Eşleşmesi
The Frequency of Autoimmune Thyroid Disease in Alopecia Areata and Vitiligo Patients
2015 ISSN: 2314-6133 SCI-Expanded
Prof. Dr. GÜLCAN SAYLAM KURTİPEK →
A Comparative Study for the Evaluation of Two Doses of Ellagic Acid on Hepatic Drug Metabolizing and Antioxidant Enzymes in the Rat
2013 ISSN: 2314-6133 SCI-Expanded 12 atıf
Prof. Dr. SERDAR KARAKURT →
The Increase of Intra-Abdominal Pressure Can Affect Intraocular Pressure
2015 ISSN: 2314-6133 SCI-Expanded
Prof. Dr. İLHAN ECE →
Strontium Chloride Can It Be a New TreatmentOption for Ulcerative Colitis
2014 ISSN: 2314-6133 SCI-Expanded
Doç. Dr. NEVİN TUZCU →
Serum Biochemistry of Lumpy Skin Disease Virus Infected Cattle
2016 ISSN: 2314-6133 SCI-Expanded
Prof. Dr. OĞUZHAN AVCI →
Genetic diversity of eight domestic goat populationraised in Turkey
2016 ISSN: 2314-6133 SSCI
Prof. Dr. VAHDETTİN ALTUNOK →
Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer Using Thermocure Lamp
2016 ISSN: 2314-6133 SCI-Expanded
Prof. Dr. GÜL TOSUN →
Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer Using Thermocure Lamp
2016 ISSN: 2314-6133 SCI-Expanded
Prof. Dr. HAYRİYE ESRA ÜLKER →
Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp
2016 ISSN: 2314-6133 SCI-Expanded Q2
Doç. Dr. FİRDEVS KAHVECİOĞLU →
Cytotoxicity Testing of Temporary Luting Cements with Two and Three Dimensional Cultures of Bovine Dental Pulp Derived Cells
2013 ISSN: 2314-6133 SCI-Expanded
Prof. Dr. HAYRİYE ESRA ÜLKER →
Effects of 16 Carbamide Peroxide Bleaching on the Surface Properties of Glazed Glassy Matrix Ceramics
2020 ISSN: 2314-6133 SCI-Expanded
Prof. Dr. NECLA DEMİR →
Real-Time Analysis of Antiproliferative Effects of Mouthwashes Containing Alcohol, Sodium Fluoride, Cetylpyridinium Chloride, and Chlorhexidine In Vitro
2021 ISSN: 2314-6133 SCI-Expanded Q2
Doç. Dr. FİRDEVS KAHVECİOĞLU →
Real-Time Analysis of Antiproliferative Effects of Mouthwashes Containing Alcohol, Sodium Fluoride, Cetylpyridinium Chloride, and Chlorhexidine In Vitro
2021 ISSN: 2314-6133 SCI-Expanded Q2
Prof. Dr. HAYRİYE ESRA ÜLKER →
Strontium Chloride: Can It Be a New Treatment Option for Ulcerative Colitis?
2014 ISSN: 2314-6133 SCI-Expanded
Prof. Dr. MEHMET TUZCU →
Bonding Effectiveness of Saliva-Contaminated Monolithic Zirconia Ceramics Using Different Decontamination Protocols
2024 ISSN: 2314-6133 ESCI
Prof. Dr. NECLA DEMİR →
Makale Bilgileri
ISSN23146133
Yayın TarihiOcak 2016
Cilt / Sayfa2016
Scopus ID2-s2.0-85008625577
Erişim🔓 Açık Erişim
Özet
Objectives. To measure the temperature increase induced during thermocure lamp setting reaction of glass carbomer and to compare it with those induced by visible light curing of a resin-modified glass ionomer and a polyacid-modified composite resin in primary and permanent teeth. Materials and Methods. Nonretentive class I cavities were prepared in extracted primary and permanent molars. Glass carbomer (GC) was placed in the cavity and set at 60°C for 60 sn using a special thermocure lamp. Resin-modified glass ionomer (RMGIC) and polyacid-modified composite resin (PMCR) were placed in the cavities and polymerized with an LED curing unit. Temperature increases during setting reactions were measured with a J-type thermocouple wire connected to a data logger. Data were examined using two-way analysis of variance and Tukey's honestly significant difference tests. Results. The use of GC resulted in temperature changes of 5.17 ± 0.92°C and 5.32 ± 0.90°C in primary and permanent teeth, respectively (p>0.05). Temperature increases were greatest in the GC group, differing significantly from those in the PMCR group (p<0.05). Conclusion. Temperature increases during polymerization and setting reactions of the materials were below the critical value in all groups. No difference was observed between primary and permanent teeth, regardless of the material used.
Yazarlar (3)
1
Firdevs Kahvecioğlu
ORCID: 0000-0003-4216-0849
2
Gül Tosun
ORCID: 0000-0003-4844-8157
3
H. E. Ülker
Kurumlar
Selçuk Üniversitesi
Selçuklu Turkey
Scimago Dergi (ISSN Eşleşmesi)
BioMed Research International
Q2
OA
SJR Skoru0,748
H-Index219
YayıncıJohn Wiley and Sons Ltd
ÜlkeUnited Kingdom
Biochemistry, Genetics and Molecular Biology (miscellaneous) (Q2)
Immunology and Microbiology (miscellaneous) (Q2)
Medicine (miscellaneous) (Q2)
Metrikler
6
Atıf
3
Yazar