CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS Eşleşti

Effect of saliva decontamination procedures on shear bond strength of a one-step adhesive system

Nigerian Journal of Clinical Practice · Eylül 2017

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Effect of saliva decontamination procedures on shear bond strength of a one-step adhesive system
Nigerian Journal of Clinical Practice · 2017 SCI-Expanded
PROFESÖR HAYRİYE ESRA ÜLKER →
Effect of saliva decontamination procedures on shear bond strength of a one-step adhesive system
Nigerian Journal of Clinical Practice · 2017 SCI-Expanded
DOÇENT FİRDEVS KAHVECİOĞLU →
Effect of saliva decontamination procedures on shear bond strength of a one step adhesive system
Nigerian Journal of Clinical Practice · 2016 SCI-Expanded
DOÇENT FİRDEVS KAHVECİOĞLU →
Effect of saliva decontamination procedures on shear bond strength of a one step adhesive system
Nigerian Journal of Clinical Practice · 2016 SCI-Expanded
PROFESÖR HAYRİYE ESRA ÜLKER →

Makale Bilgileri

DergiNigerian Journal of Clinical Practice
Yayın TarihiEylül 2017
Cilt / Sayfa20 · 1201-1205
Özet Aim: To evaluate the effect of different saliva decontamination procedures on the shear bond strength of a one-step universal adhesive system (Single Bond™ Universal Adhesive, 3M ESPE, St. Paul, MN, USA). Materials and Methods: The occlusal surfaces of 75 human third molars were ground to expose dentin. The teeth were divided into the following groups: Group 1 (control group): Single Bond™ Universal Adhesive was applied to the prepared tooth according to the manufacturer's recommendations and light cured; no contamination procedure was performed. Group 2: Bonding, light curing, saliva contamination, and dry. Group 3: Bonding, light curing, saliva contamination, rinse, and dry. Group 4: After the procedure performed in Group 2, reapplication of bonding. Group 5: After the procedure performed in Group 3, reapplication of bonding. Then, composite resins were applied with cylindrical-shaped plastic matrixes and light cured. For shear bond testing, a notch-shaped force transducer apparatus was applied to each specimen at the interface between the tooth and composite until failure occurred. The data were statistically analyzed using one-way ANOVA. Results: One-way ANOVA revealed significant differences in shear bond strength between the control group and experimental Groups 2 and 4 (P < 0.05). No significant difference was found for experimental Groups 3 and 5 when compared to the control group (P > 0.05). Conclusion: The present in vitro study showed that water rinsing is necessary if cured adhesive resin is contaminated with saliva to ensure adequate bond strength.

Yazarlar (4)

1
E. Ülker
2
S. Bilgin
3
Firdevs Kahvecioğlu
ORCID: 0000-0003-4216-0849
4
A. Erkan

Anahtar Kelimeler

Decontamination one-step adhesive system shear bond strength

Kurumlar

Selçuk Üniversitesi
Selçuklu Turkey

Metrikler

6
Atıf
4
Yazar
3
Anahtar Kelime

Sistemimizdeki Yazarlar