HPLC and LC-MS/MS measurement methods for the quantification of asymmetric dimethylarginine (ADMA) and related metabolites

Turkish Journal of Biochemistry · Ağustos 2021

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
HPLC and LC-MS/MS measurement methods for the quantification of asymmetric dimethylarginine (ADMA) and related metabolites
Turkish Journal of Biochemistry · 2021 SCI-Expanded
PROFESÖR SEDAT ABUŞOĞLU →
HPLC and LC-MS/MS measurement methods for the quantification of asymmetric dimethylarginine (ADMA) and related metabolites
Turkish Journal of Biochemistry · 2021 SCI-Expanded
DOÇENT GÜLSÜM ABUŞOĞLU →
HPLC and LC-MS/MS measurement methods for the quantification of asymmetric dimethylarginine (ADMA) and related metabolites
Turkish Journal of Biochemistry · 2021 SCI-Expanded
PROFESÖR ALİ ÜNLÜ →

Makale Bilgileri

DergiTurkish Journal of Biochemistry
Yayın TarihiAğustos 2021
Cilt / Sayfa46 · 327-347
Erişim🔓 Açık Erişim
Özet Methyl arginine derivatives such as asymmetric dimethylarginine (ADMA), symmetric dimethylarginine (SDMA), L-N-monomethyl arginine (L-NMMA) are formed by proteolytic catalysis following methylation of arginine residues in proteins. These metabolites reduce NO production. Methylated arginines are an important biomarker for various diseases such as cardiovascular and renal diseases. Therefore, many methods have been developed to reliably and accurately measure the levels of these metabolites. This review, HPLC and LC-MS/MS methods developed for the measurement of methylarginine derivatives are discussed. In HPLC methods, solid phase extraction, derivatization and subsequent separation by reverse phase chromatography were performed. Since these metabolites are polar, they are difficult to retain in conventional reverse phase columns. In addition, as serum levels of these metabolites are low, sensitivity problems have been observed in HPLC methods. Derivatization has been applied to eliminate these problems. However, there have been problems with the stability of derivatives formed. Another important problem is that the separation of stereoisomer ADMA and SDMA can only be achieved chromatographically. Tandem mass spectrometric methods are accurate, selective, sensitive and rapid since analytes are separated depending on m/z ratios rather than chromatographic separation. Therefore, tandem mass spectrometry methods might be considered as the goal standard for these analytes.

Yazarlar (4)

1
Ali Ünlü
ORCID: 0000-0002-9991-3939
2
Duygu Eryavuz Onmaz
ORCID: 0000-0001-8564-1824
3
Sedat Abusoglu
ORCID: 0000-0002-2984-0527
4
Gulsum Abusoglu

Anahtar Kelimeler

Chromatography Methodology Methylated arginine Nitric oxide Tandem mass spectrometry

Kurumlar

Selçuk Tip Fakültesi
Konya Turkey
Selçuk Üniversitesi
Selçuklu Turkey

Metrikler

3
Atıf
4
Yazar
5
Anahtar Kelime

Sistemimizdeki Yazarlar