Scopus
YÖKSİS Eşleşti
The usefulness of plasma asymmetric dimethylarginine (ADMA) levels and tissue doppler echocardiography for heart function in term infants born to mothers with gestational diabetes mellitus
Journal of Maternal-Fetal and Neonatal Medicine · Kasım 2013
YÖKSİS Kayıtları
The usefulness of plasma asymmetric dimethylarginine ADMA levels and tissue doppler echocardiography for heart function in term infants born to mothers with gestational diabetes mellitus
Journal of Maternal-Fetal and Neonatal Medicine · 2013 SCI-Expanded 2 atıf
PROFESÖR HÜSAMETTİN VATANSEV →
Makale Bilgileri
DergiJournal of Maternal-Fetal and Neonatal Medicine
Yayın TarihiKasım 2013
Cilt / Sayfa26 · 1742-1748
Scopus ID2-s2.0-84886615021
Özet
Objective: The aim of this study was to examine whether asymmetric dimethylarginine (ADMA) concentrations are associated with ventricular function in the infants of mothers with gestational diabetes. Method: Twenty-five term newborns of mothers with gestational diabetes and term newborns as the control group (n = 25) with normal general health status were evaluated at two time points, on the 3rd postnatal day, at the 3th months. Echocardiographic evaluations of all participants were performed and ADMA level was measured. Results: In the first analysis, 10 patients (40%) had a septal thickness of 6 mm or more, indicating septal hypertrophy. In the first and second analysis, interventricular septum end-diastolic thickness (IVSTd) and the left ventricular posterior wall end-diastolic thickness (LVPWTd) in the patient group were higher than the control group. ADMA level measurement was not significantly different between the groups the first and second analysis. There was no difference in ADMA levels of the group with septal thickness ≥6 mm and the group with <6 mm. Conclusion: Newborn cardiac wall thickness was increased in pregnancies complicated by Gestational diabetes mellitus (GDM), and the increase was independent of glycemic control. Diastolic newborn cardiac function was impaired in GDM, and this effect was independent of septal thickness. We found no association between ADMA levels and cardiac systolic, diastolic functions or septum thickness in the GDM newborn. © 2013 Informa UK Ltd.
Yazarlar (5)
1
Derya Arslan
2
B. Oran
3
Hüsamettin Vatansev
4
Derya Çimen
5
O. Güvenç
Anahtar Kelimeler
Asymmetric dimethylarginine
Gestational diabetes
Newborn
Tissue Doppler imaging
Kurumlar
Selçuk Üniversitesi
Selçuklu Turkey
Metrikler
14
Atıf
5
Yazar
4
Anahtar Kelime