Scopus
YÖKSİS DOI Eşleşti
SJR Q3
Surface roughness and morphologic changes of zirconia following different surface treatments
Photomedicine and Laser Surgery · Haziran 2012
YÖKSİS Kayıtları
Surface Roughness and Morphologic Changes of Zirconia Following Different Surface Treatments
Photomedicine and Laser Surgery · 2012 SCI-Expanded
Prof. Dr. NECLA DEMİR →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Surface Roughness and Morphologic Changes of Zirconia Following Different Surface Treatments
2012 ISSN: 1549-5418 SCI-Expanded
Prof. Dr. NECLA DEMİR →
Effect of Different Surface Treatments on the Bond Strength of Lithium Disilicate Ceramic to the Zirconia Core
2016 ISSN: 1549-5418 SCI-Expanded
Prof. Dr. NECLA DEMİR →
Effect of Different Surface Treatments on the Bond Strength of Lithium Disilicate Ceramic to the Zirconia Core
2016 ISSN: 1549-5418 SCI-Expanded Q3
Doç. Dr. TUBA YILMAZ SAVAŞ →
A New Method for Investigation of Different Tissues Using Femtosecond Laser Mass Spectrometry
2018 ISSN: 1549-5418 SCI-Expanded Q2
Doç. Dr. YASEMİN GÜNDOĞDU KABAKCI →
Makale Bilgileri
ISSN15495418
Yayın TarihiHaziran 2012
Cilt / Sayfa30 · 339-345
Scopus ID2-s2.0-84862230304
Özet
Objective: The aim of this study was to evaluate the roughness and morphology of zirconia after air abrasion and erbium:yttrium-aluminum-garnet (Er:YAG) laser application of different intensities. Background data: Although surface roughness is important to obtain micromechanical retention, it is unclear which surface treatment is most appropriate for zirconia. Methods: Fifty sintered zirconia specimens were divided into five groups (n = 10). The following treatments were applied: control, Er:YAG laser irradiation with different energy intensities (200, 300, and 400 mJ), and air abrasion with aluminum oxide (Al 2O 3) particles (110 μm). Morphologic changes after surface treatments were examined in microscope analyses. Then, the surface roughness (Ra in μm) of the specimens was evaluated using a surface texture measuring instrument. Roughness data were analyzed using one-way analysis of variance (ANOVA) and Tukey's honestly significant difference (HSD) test ( p = 0.05). Results: Results of microscope analyses revealed changes in surface morphology after surface treatments, including the formation of rare pits in the 400mJ laser group and the formation of microretentive grooves in the air abrasion group. According to the results of the statistical analysis, the mean surface roughness value for the air abrasion group was significantly higher than that of the other groups ( p < 0.001). Except for the air abrasion group, there were no statistically significant differences within other groups ( p > 0.05). Conclusions: According to the results of the statistical and microscopic analyses, 400 mJ Er:YAG laser energy or air abrasion can be used to obtain micromechanical retention prior to luting; however, air abrasion is the most effective surface treatment method. © 2012 Mary Ann Liebert, Inc.
Yazarlar (3)
1
Necla Demir
ORCID: 0000-0003-0927-6962
2
M. Gülce Subasşi
3
A. Nilgun Ozturk
Kurumlar
Selçuk Üniversitesi
Selçuklu Turkey
Scimago Dergi (ISSN Eşleşmesi)
Photomedicine and Laser Surgery
Q3
SJR Skoru0,469
H-Index84
YayıncıMary Ann Liebert Inc.
ÜlkeUnited States
Biomedical Engineering (Q3)
Radiology, Nuclear Medicine and Imaging (Q3)
Metrikler
43
Atıf
3
Yazar