CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS Eşleşti

Apically extruded debris during root canal preparation using Vortex Blue, K3XF, ProTaper Next and Reciproc instruments

International Endodontic Journal · Aralık 2016

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Apically extruded debris during root canal preparation using Vortex Blue, K3XF, ProTaper Next and Reciproc instruments
International Endodontic Journal · 2015 SCI-Expanded
DOÇENT AHMET AKTI →
Apically extruded debris during root canal preparation using Vortex Blue, K3XF, ProTaper Next and Reciproc instruments
International Endodontic Journal · 2016 SCI-Expanded
DOÇENT AHMET AKTI →
Apically extruded debris during root canal preparation using Vortex Blue, K3XF, ProTaper Next and Reciproc instruments
International Endodontic Journal · 2016 SCI-Expanded
DOÇENT AHMET AKTI →

Makale Bilgileri

DergiInternational Endodontic Journal
Yayın TarihiAralık 2016
Cilt / Sayfa49 · 1183-1187
Özet Aim: To assess the amount of debris extruded apically during root canal preparation using various nickel–titanium instrumentation systems. Methodology: Sixty extracted single-rooted mandibular premolar human teeth were randomly assigned to four groups (n = 15 teeth for each group). The canals were then instrumented with the following instrument systems: Vortex Blue (VB; Dentsply Tulsa Dental, Tulsa, OK, USA), K3XF (SybronEndo, Orange, CA, USA), Reciproc (VDW, Munich, Germany) and ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland). Apically extruded debris during instrumentation was collected into pre-weighed Eppendorf tubes. The Eppendorf tubes were then stored in an incubator at 70 °C for 5 days. The weight of the dry extruded debris was established by subtracting the pre-instrumentation and post-instrumentation weight of the Eppendorf tubes for each group. The data were analysed using one-way analysis of variance (anova) and Tukey's post hoc tests. Results: Vortex Blue and PTN files were associated with significantly less apically extruded debris than the K3XF and Reciproc files (P < 0.05), but there was no significant difference between the VB and PTN files or between the K3XF and Reciproc files (P > 0.05). Conclusions: All instruments were associated with apical extrusion of debris. VB and PTN files were associated with less debris extrusion compared to the other systems.

Yazarlar (8)

1
H. S. Topçuoğlu
2
R. Zan
3
F. Akpek
4
G. Topçuoğlu
5
Ulusan
6
Ahmet Akti
ORCID: 0000-0002-3447-0065
7
S. Düzgün
8
M. Ağırnaslıgil

Anahtar Kelimeler

canal preparation debris extrusion K3XF Vortex Blue

Kurumlar

Cumhuriyet Üniversitesi
Sivas Turkey
Erciyes Üniversitesi
Kayseri Turkey

Metrikler

35
Atıf
8
Yazar
4
Anahtar Kelime

Sistemimizdeki Yazarlar