The effects of 21 and 23 milimeter aortic valve prosthesis on hemodynamic performance and functional capacity in young adults
Pakistan Journal of Medical Sciences · Mart 2014
YÖKSİS Kayıtları
The effects of 21 and 23 milimeter aortic valve prosthesis on hemodynamic performance and functional capacity in young adults
Pakistan Journal of Medical Sciences · 2014 SCI-Expanded
DOÇENT ÖMER FARUK ÇİÇEK →
The effects of 21 and 23 milimeter aortic valve prosthesis on hemodynamic performance and functional capacity in young adults
Pakistan Journal of Medical Sciences · 2014 SCI-Expanded
DOÇENT ÖMER FARUK ÇİÇEK →
Makale Bilgileri
DergiPakistan Journal of Medical Sciences
Yayın TarihiMart 2014
Cilt / Sayfa30 · 356-360
Scopus ID2-s2.0-84896880239
Özet
Objective: Early and medium-term improvement of functional capacity and regression of left ventricular hypertrophy was evaluated in the young adult patient group following application of 21 mm or 23 mm bileaflet aortic mechanical valve prosthesis due to aortic stenosis. Methods: Twenty two patients (10 male, 12 female; mean age 27+-8.2 (19-43)) who underwent isolated aortic valve replacement due to rheumatic aortic stenosis, were included in the study. 21 mm and 23 mm bileaflet mechanical prosthesis was used respectively in eight and fourteen patients. The mean body surface area was 1.86 m2 and 1.68 m2 respectively in 23 mm and 21 mm prosthesis while 1.73 ±0.25 m2 for the whole group. Functional capacity was New York Heart Association (NYHA) class II in 9 patients and class III in thirteen patients. Implantation was performed without enlarging the aortic root in all except four patients. In all patients transvalvular gradients, effective orifice area and the diameter of left ventricle were measured with transthoracic echocardiography during rest and after maximal exercise. Mean followup was 34±12 months (range 11-57 months). Results: There were no postoperative complications or deaths. All the patients were assessed as NYHA class I with regards to functional capacity (p=0.01). Significant improvements were determined in postoperative mean transvalvular gradient (p=0.005) and left ventricular mass index (p=0.01) when compared with preoperative values. Conclusion: Our findings show that replacement with 21 mm and 23 mm mechanical prosthesis provides a significant improvement in regression of symptoms and increase of functional capacity in young adults in early and mid-period without increasing mortality and morbidity.
Yazarlar (6)
1
Ali Ümit Yener
ORCID: 0000-0002-0779-2122
2
Sedat Özcan
3
Ali Baran Budak
4
Serhat Bahadir Genc
5
Muhammed Turgut Alper Özkan
6
Ömer Faruk Çiçek
ORCID: 0000-0002-4675-3273
Anahtar Kelimeler
Aortic valve
Aortic valve stenosis
Echocardiography
Transvalvular gradient
Valve surgery
Kurumlar
Ankara Numune Education and Research Hospital
Ankara Turkey
Ankara Yuksek Ihtisas Education and Research Hospital
Ankara Turkey
Çanakkale Onsekiz Mart Üniversitesi
Canakkale Turkey