CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus 🔓 Açık Erişim YÖKSİS Eşleşti

An advanced hybrid pre-filtering/in-loop-filtering based PLL under adverse grid conditions

Engineering Science and Technology an International Journal · Ekim 2021

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
An advanced hybrid pre-filtering/in-loop-filtering based PLL under adverse grid conditions
Engineering Science and Technology-An International Journal-JESTECH · 2021 SCI-Expanded
DOÇENT HULUSİ KARACA →
An advanced hybrid pre-filtering/in-loop-filtering based PLL under adverse grid conditions
Engineering Science and Technology-An International Journal-JESTECH · 2021 SCI-Expanded
DOKTOR ÖĞRETİM ÜYESİ FEHMİ SEVİLMİŞ →

Makale Bilgileri

DergiEngineering Science and Technology an International Journal
Yayın TarihiEkim 2021
Cilt / Sayfa24 · 1144-1152
Erişim🔓 Açık Erişim
Özet The amplitude, frequency and phase angle of the grid voltage are essential three components to ensure synchronization for grid interactive inverters. Synchronous reference frame-phase locked loop (SRF-PLL) is widely used to obtain these components. Although the SRF-PLL shows a perfect performance under ideal grid conditions, its performance deteriorates under unbalanced and distorted grid conditions. Therefore, researchers have been working to provide more advanced PLL methods. A dual third order generalized integrator PLL (DTOGI-PLL) and quasi-type-1 PLL (QT1-PLL) are two PLL methods that have come to the fore in grid synchronization recently. As with any method, these PLL methods have both advantages and disadvantages. The aim of this study is to integrate the advantages of the two methods, and to develop a new PLL method with better performance than these two methods. It means that the proposed PLL has the adaptive filtering capability of the DTOGI-PLL and fast transient response of the QT1-PLL. The effectiveness of the proposed PLL is confirmed by experimental results. The experimental results demonstrate that the proposed PLL is a more effective method than the DTOGI-PLL and QT1-PLL under adverse grid conditions.

Yazarlar (2)

1
Fehmi Sevilmiş
ORCID: 0000-0002-6059-9583
2
Hulusi Karaca

Anahtar Kelimeler

Adverse grid conditions Dual third-order generalized integrator (DTOGI) Phase locked loop (PLL) Quasi-type-1 (QT1) Synchronization

Kurumlar

Selçuk Üniversitesi
Selçuklu Turkey

Metrikler

17
Atıf
2
Yazar
5
Anahtar Kelime

Sistemimizdeki Yazarlar