A sensitive amperometric detection of neurotransmitter acetylcholine using carbon dot-modified carbon paste electrode

Biotechnology and Applied Biochemistry · Şubat 2021

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
A sensitive amperometric detection of neurotransmitter acetylcholine using carbon dot-modified carbon paste electrode
Biotechnology and Applied Biochemistry · 2021 SCI-Expanded
Doç. Dr. SALİHA DİNÇ →
A sensitive amperometric detection of neurotransmitter acetylcholine using carbon dot-modified carbon paste electrode
Biotechnology and Applied Biochemistry · 2021 SCI-Expanded
Prof. Dr. MUSTAFA ÖZMEN →
YÖKSİS ISSN Eşleşmesi

Bu dergide (ISSN eşleşmesi) kurumun 1 kaydı bulundu.

YÖKSİS Kayıtları — ISSN Eşleşmesi
A sensitive amperometric detection of neurotransmitter acetylcholine using carbon dot-modified carbon paste electrode
2021 ISSN: 0885-4513 SCI-Expanded Q3
Doç. Dr. SALİHA DİNÇ →

Makale Bilgileri

ISSN08854513
Yayın TarihiŞubat 2021
Cilt / Sayfa68 · 20-29
Özet Acetylcholine is a neurotransmitter, which is located at the intersections of the nerve and muscles in the lymph nodes of the internal organs motor systems and in various parts of the central nervous system. A decrease of acetylcholine in brain is associated with Alzheimer‘s disease. That is why it is an important agent for this disease. In this study, a bienzymatic biosensor system with acetylcholine esterase and choline oxidase was prepared with carbon paste electrode modified with carbon nano Dot-(3-Aminopropyl) triethoxysilane (CDs-APTES) for determination of the amount of acetylcholine. Acetylcholine esterase and choline oxidase enzymes were immobilized onto a modified carbon paste electrode by cross-linking with glutaraldehyde. Determination of acetylcholine was carried out by the oxidation of enzymatically produced H<inf>2</inf>O<inf>2</inf> at 0.4 V versus Ag/AgCl. The effect of temperature, pH, and substrate concentration on the acetylcholine response of the prepared biosensor was investigated. In addition, the optimum CDs-APTES amount, the linear operating range of the biosensor, and the interference effect were also investigated.

Yazarlar (4)

1
Onur Can Bodur
2
Saliha Dinç
3
Mustafa Ozmen
ORCID: 0000-0001-5117-9168
4
Fatma Arslan

Anahtar Kelimeler

acetylcholine esterase biosensor choline oxidase

Kurumlar

Gazi Üniversitesi
Ankara Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Scimago Dergi (ISSN Eşleşmesi)
Biotechnology and Applied Biochemistry
Q2
SJR Skoru0,738
H-Index85
YayıncıWiley-Blackwell
ÜlkeUnited States
Applied Microbiology and Biotechnology (Q2)
Bioengineering (Q2)
Biomedical Engineering (Q2)
Biotechnology (Q2)
Drug Discovery (Q2)
Medicine (miscellaneous) (Q2)
Process Chemistry and Technology (Q2)
Molecular Medicine (Q3)
Dergi sayfasına git

Metrikler

30
Atıf
4
Yazar
3
Anahtar Kelime

Sistemimizdeki Yazarlar