CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus 🔓 Açık Erişim YÖKSİS Eşleşti

Prospective ECG-gated high-pitch dual-source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities: Radiation dose and diagnostic efficacy in a pediatric population

Diagnostic and Interventional Imaging · Kasım 2016

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Prospective ECG gated high pitch dual source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities Radiation dose and diagnostic efficacy in a pediatric population
Diagnostic and Interventional Imaging · 2016 SCI-Expanded
PROFESÖR MEHMET ALKILIÇ HORASANI ÖÇ →
Prospective ECG gated high pitch dual source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities Radiation dose and diagnostic efficacy in a pediatric population
Diagnostic and Interventional Imaging · 2016 SCI-Expanded
PROFESÖR MUSTAFA KOPLAY →

Makale Bilgileri

DergiDiagnostic and Interventional Imaging
Yayın TarihiKasım 2016
Cilt / Sayfa97 · 1141-1150
Erişim🔓 Açık Erişim
Özet Purpose: The goal of this study was to investigate the radiation dose and diagnostic efficacy of cardiac computed tomography angiography (CCTA) using prospective ECG-gated high-pitch dual-source computed tomography (DSCT) in the diagnosis of congenital cardiovascular abnormalities in pediatric population. Materials and methods: One hundred five pediatric patients who were clinically diagnosed with congenital heart disease with suspected extracardiac vascular abnormalities were included in the study. All CCTAs were performed on a 128×2-section DSCT scanner. CCTA findings were compared with surgical and/or conventional cardiac angiography findings. Dose-length product (DLP) and effective doses (ED) were calculated for each patient. Patients were divided into 4 groups by age, and ED and DLP values were compared among groups. The image quality was evaluated using a five-point scale. Results: CCTA showed 173 abnormalities in 105 patients. There were 2 patients with false positive and 3 with false negative findings. The sensitivity and specificity of CCTA were 98.3% and 99.9%, respectively. The positive predictive value and negative predictive value of CCT were 98.9% and 99.9%, respectively. The average DLP and ED values were 15.6±9.6 (SD) mGy.cm and 0.34±0.10 (SD) mSv, respectively. The mean image quality score was 4.8±0.5 (SD) in all patients. The inter-observer agreement for the image quality scores was good (κ=0.80). al. Conclusion: CCTA is an excellent imaging modality for evaluation of cardiovascular abnormalities and provides excellent image quality with very low radiation exposure when low-dose prospective ECG-triggered high-pitch DSCT is used.

Yazarlar (8)

1
M. Koplay
ORCID: 0000-0001-7513-4968
2
O. Kizilca
3
Derya Çimen
4
Mesut Sivri
5
Hasan Erdogan
6
O. Güvenç
7
Mehmet Oc
ORCID: 0000-0002-7832-3067
8
B. Oran

Anahtar Kelimeler

Cardiac CT Cardiovascular Congenital Dual-source CT Prospective ECG-triggered

Kurumlar

Horasan State Hospital
Erzurum Turkey
Selçuk Üniversitesi
Selçuklu Turkey

Metrikler

19
Atıf
8
Yazar
5
Anahtar Kelime

Sistemimizdeki Yazarlar