Separation and identification of different therapeutic pharmaceutical drugs on humic acid-based HPLC column: Method optimization using central composite design

Journal of Separation Science · Temmuz 2023

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Separation and identification of different therapeutic pharmaceutical drugs on humic acid‐based HPLC column: Method optimization using central composite design
Wiley · 2023 SCI-Expanded
PROFESÖR HAMİDE FİLİZ AYYILDIZ →
Separation and identification of different therapeutic pharmaceutical drugs on humic acid‐based HPLC column: Method optimization using central composite design
Wiley · 2023 SCI-Expanded
PROFESÖR HÜSEYİN KARA →

Makale Bilgileri

DergiJournal of Separation Science
Yayın TarihiTemmuz 2023
Cilt / Sayfa46
Erişim🔓 Açık Erişim
Özet Multimode chromatographic separations are highly desirable in pharmaceutical and environmental sciences. Current study deals with the application of newly developed mixed-mode end capped-immobilized humic acid onto an aminopropyl silica based chromatographic column for separation and identification of six drugs belonging to different therapeutic groups for its applicability in pharmaceutical industries. For this, central composite design was used to evaluate the separation and resolution by optimization of three most effective parameters (acetonitrile%, flow rate, and pH of mobile phase). Second-order quadratic model was used to evaluate their effect on resolution of peaks; the probability value (<0.05) obtained from analysis of variance suggested the best applicability of the model. Desirability function was applied to calculate optimum conditions (44.8% acetonitrile, 1.75 mL/min of flow rate, and 7.5 pH) required to achieve maximum separation with good resolution within 11 min. The method was validated for linearity, precision accuracy, selectivity, and sensitivity. The results revealed a highly precise (coefficient of variance > 1%), linear (R2 = 0.99), and highly selective method. Moreover, the limit of detection/quantification values revealed acceptable sensitivity of the method. The developed column was compared for its efficiency with a commercially available column and found to be highly applicable for industrial applications.

Yazarlar (4)

1
Hamide Filiz Ayyildiz
2
Fakhar N. Memon
ORCID: 0000-0002-8700-5597
3
Irfan Ali Mangi
4
Huseyin Kara

Anahtar Kelimeler

aminopropyl silica central composite design chromatography humic acid therapeutic drugs

Kurumlar

Selçuk Üniversitesi
Selçuklu Turkey
University of Karachi
Karachi Pakistan

Metrikler

1
Atıf
4
Yazar
5
Anahtar Kelime

Sistemimizdeki Yazarlar