Investigation of the effect of thyroid collar, radiation safety glasses, and lead apron on radiation dose in cone beam CT

Dentomaxillofacial Radiology · Mart 2025

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Investigation of the effect of thyroid collar, radiation safety glasses, and lead apron on radiation dose in cone beam CT
Dentomaxillofacial Radiology · 2025 SCI-Expanded
DOÇENT DERYA İÇÖZ →
Investigation of the effect of thyroid collar, radiation safety glasses, and lead apron on radiation dose in cone beam CT
Dentomaxillofacial Radiology · 2025 SCI-Expanded
DOÇENT OSMAN VEFA GÜL →

Makale Bilgileri

DergiDentomaxillofacial Radiology
Yayın TarihiMart 2025
Cilt / Sayfa54 · 231-238
Özet Objectives: Due to the increasing use of cone-beam CT (CBCT) in dentistry and considering the effects of radiation on radiosensitive organs, the aim of this study was to investigate the effect of shielding on absorbed dose of eyes, thyroid, and breasts in scans conducted with different parameters using 2 different fields of view (FOV). Methods: Dose measurements were calculated on a tissue-equivalent female phantom by repeating each scanning parameter 3 times and placing at least 2 thermoluminescent dosimeters (TLD) on each organ, with the averages then taken. The same CBCT scans were performed in 2 different FOV with shielding including thyroid collar, radiation safety glasses, and lead apron and without shielding. The differences between them were analysed statistically. Descriptive statistics and the Wilcoxon test were used for data analysis. Results: The difference between measurements with and without shielding was statistically significant for all scans (P <. 001). The dose reduction associated with the use of shielding ranged from 26.81% to 52.95%. The dose related to the FOV has shown a significant increase, ranging from 8.30% to 623.54%, due to both the variation in the area affected by the primary beam on the organs and changes in the amount of radiation. Conclusion: There are significant differences in the absorbed dose depending on shielding and FOV usage. Therefore, the CBCT imaging protocol should be optimized by the operator, and special attention should be paid to the use of thyroid collars and radiation safety glasses, considering their effects on image quality.

Yazarlar (2)

1
Derya Icoz
ORCID: 0000-0001-8043-288X
2
Osman Vefa Gul
ORCID: 0000-0002-6773-3132

Anahtar Kelimeler

cone-beam CT radiation dose radiation dosimetry radiation protection

Kurumlar

Selçuk Tip Fakültesi
Konya Turkey
Selçuk Üniversitesi
Selçuklu Turkey