CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS Eşleşti

Determination of Cobalt in Tap Water by Deep Eutectic Solvent-Dithizone Assisted Liquid Phase Microextraction (LPME) Preconcentration with Flame Atomic Absorption Spectrometry (FAAS)

Analytical Letters · Ocak 2026

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Determination of Cobalt in Tap Water by Deep Eutectic Solvent-Dithizone Assisted Liquid Phase Microextraction (LPME) Preconcentration with Flame Atomic Absorption Spectrometry (FAAS)
Analytical Letters · 2025 SCI-Expanded
DOKTOR ÖĞRETİM ÜYESİ TUĞÇE GÖVER →

Makale Bilgileri

DergiAnalytical Letters
Yayın TarihiOcak 2026
Cilt / Sayfa59 · 57-68
Özet This study aimed to develop an analytical method for preparing samples to preconcentrate cobalt from water in advance for determination using flame atomic absorption spectrometry (FAAS). The aforementioned outcome was attained through the complexing of cobalt ions with dithizone (Co-DTZ) and subsequently extracting the resulting complex from aqueous solution using a deep eutectic solvent (DES). The DES/DTZ probe was used as a complexing and extracting agent in the developed liquid phase microextraction (LPME) procedure. The most suitable experimental conditions were determined for the highest extraction efficiency. Consequently, 8.0 mL of standard/sample solution was adjusted to pH 6.0 using 1.0 mL of phthalate buffer. 250 µL of the DES/DTZ probe (10 mL DES: 5.0 mg DTZ) was added to the aqueous solution to extract cobalt with the best efficiency. The DES/DTZ-LPME-FAAS system achieved a detection limit of 9.6 µg/L with a wide linear working range between 30 and 500 µg/L by applying the optimum procedure. The relative standard deviation of the proposed method was 6.9% for a 30 µg/L cobalt standard. Spike recovery experiments were conducted with tap water to evaluate the accuracy and feasibility of the developed method. By performing matrix matching, the results demonstrated good recoveries from 90% to 112%.

Yazarlar (7)

1
Aslı Ağbulak
2
Yağmur Kılınç
3
Buse Tuğba Zaman
4
Tuğçe Göver
5
Melike Atakol
6
Fatma Turak
7
Sezgin Bakırdere

Anahtar Kelimeler

Cobalt deep eutective solvent dithizone flame atomic absorption spectrometry (FAAS) liquid phase microextraction (LPME)

Kurumlar

Bülent Ecevit University
Zonguldak Turkey
İstinye Üniversitesi
Istanbul Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Turkish Academy of Sciences (TUBA)
Ankara Turkey
Yıldız Teknik Üniversitesi
Istanbul Turkey

Metrikler

1
Atıf
7
Yazar
5
Anahtar Kelime