CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS Eşleşti

Fluorimetric methods for determination of aluminum in water resources utilizing newly synthesized N,N'-bis(2,5-dihydroxybenzylidene)-4,4′-diamino diphenyl ether

Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy · Kasım 2024

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Fluorimetric methods for determination of aluminum in water resources utilizing newly synthesized N,N-bis(2,5-dihydroxybenzylidene)-4,4′-diamino diphenyl ether
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2024 SCI
ÖĞRETİM GÖREVLİSİ HAVVA NUR TATLI →
Fluorimetric methods for determination of aluminum in water resources utilizing newly synthesized N,N-bis(2,5-dihydroxybenzylidene)-4,4′-diamino diphenyl ether
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2024 SSCI
PROFESÖR MUSTAFA ŞAHİN →

Makale Bilgileri

DergiSpectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy
Yayın TarihiKasım 2024
Cilt / Sayfa321
Özet Industrial waste contaimnation of water sources is a serious environmental problem. As a result, it's critical to identify metallic contamination in water with precision, sensitivity, and accuracy. In acetonitrile, the fluorimetric parameters of N,N-'bis(2,5-dihydroxybenzylidene)-4,4′-diamino diphenyl ether (DHDPE) and aluminum complex were determined. In the acetonitrile medium, the best fluorescence intensity of the DHDPE-Al complex was observed at λex = 280 nm, λem = 391 nm (excitation and emission wavelengths). For optimum complex formation, the ideal pH, duration, and temperature were 4.5, 20 min, and 25 °C, respectively. Within the ranges of 0.027–0.27 and 0.27–2.70 ppm aluminum concentrations, [Al3+]-F.I. Calibration graphs were linear. The fluorimetric aluminum measurement method was applied to diverse water sources using the newly synthesized macro molecular Schiff base DHDPE as the ligand. The aluminum concentration in water inflow to KOSKI (Konya Water and Sewerage Administration) was doubled as a result of the examination when compared to other samples of water.

Yazarlar (5)

1
Havva Nur Tatli
2
S. Beniz Gunduz
3
Mustafa Şahin
4
Elif Esra Altuner
5
Umar Ali Dar

Anahtar Kelimeler

4′-diamino diphenyl ether Aluminum N,N'-bis(2,5-dihydroxy benzylidene)-4 Schiff bases Spectrofluorimetry Water contaminations

Kurumlar

Başkent Üniversitesi
Ankara Turkey
Government College of Engineering and Technology
Ganderbal India
Kocaeli Health and Technology University
Kocaeli Turkey
Selçuk Üniversitesi
Selçuklu Turkey