CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS Eşleşti

Evaluation of the effect of fasting on intraocular pressure, anterior segment parameters and density of crystalline lens and cornea

International Ophthalmology · Kasım 2020

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Evaluation of the effect of fasting on intraocular pressure, anterior segment parameters and density of crystalline lens and cornea
International Ophthalmology · 2020 SCI-Expanded
DOÇENT ABDULLAH BEYOĞLU →
Evaluation of the Effect of Fasting on Intraocular Pressure, Anterior Segment Parameters and Density of Cristalline Lens and Cornea
INTERNATIONAL OPHTHALMOLOGY · 2020 SCI-Expanded
DOÇENT ABDULLAH BEYOĞLU →

Makale Bilgileri

DergiInternational Ophthalmology
Yayın TarihiKasım 2020
Cilt / Sayfa40 · 2987-2994
Özet Purpose: To evaluate the effect of fasting on anterior chamber depth, anterior chamber volume and corneal and lens density by Scheimpflug technology and to measure intraocular pressure changes. Methods: Totals of 50 healthy fasting individuals in Ramadan (study group) and 50 healthy non-fasting subjects (control group) were included. Central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), corneal density (CD) and lens density (LD) were evaluated with Scheimpflug technology. Intraocular pressure (IOP) was measured with applanation tonometry. Both eyes of each participant were examined and also compared. Results: Comparison of groups: There was a statistically significant difference between CD, ACD, ACV and IOP (respectively, right/left eye: fasting: CD: 12.81 ± 0.76/12.73 ± 0.73; ACD: 2.92 ± 0.37 mm/2.93 ± 0.37 mm; ACV: 168.3 ± 41.82 mm3/183.34 ± 32.46 mm3; IOP: 13.80 ± 1.22 mmHg/14.88 ± 2.73 mmHg; non-fasting: CD: 13.28 ± 1.01/13.17 ± 0.77; ACD: 3.06 ± 0.31 mm/3.07 ± 0.31 mm; ACV: 167.46 ± 42.92 mm3/180.68 ± 31.45 mm3; IOP: 13.60 ± 1.65 mmHg/14.74 ± 2.93 mmHg) values on the right side (p < 0.01, p = 0.03, p = 0.04, p = 0.01, respectively). Although there was a statistically significant difference between the ACV, CD and IOP values on the left side (p < 0.01, p = 0.03, p = 0.01, respectively), no statistical significance was found for the ACV value on the left side (p = 0.08). Conclusion: The results demonstrated that, while fasting did not lead to any change in LD and CCT, it caused a small decrease in ACD and ACV, and a significant decrease in CD and IOP values. Scheimpflug technology seems to be a valuable tool for the evaluation of anterior segment changes in patients who are fasting.

Yazarlar (3)

1
Abdullah Beyoğlu
2
Yalçın Karaküçük
3
Aysegul Comez
ORCID: 0000-0002-2628-9426

Anahtar Kelimeler

Corneal density Dehydration Fasting İntraocular pressure Lens density Scheimpflug technology

Kurumlar

Kahramanmaras Sütçü Imam Üniversitesi
Kahramanmaras Turkey
Selçuk Üniversitesi
Selçuklu Turkey

Metrikler

5
Atıf
3
Yazar
6
Anahtar Kelime

Sistemimizdeki Yazarlar