CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS Eşleşti

Is a neutral head position as effective as head rotation during landmark-guided internal jugular vein cannulation? Results of a randomized controlled clinical trial

Journal of Cardiothoracic and Vascular Anesthesia · Aralık 2012

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Is a Neutral Head Position as Effective as Head Rotation During Landmark Guided Internal Jugular Vein Cannulation Results of a Randomized Controlled Clinical Trial
Journal of Cardiothoracic and Vascular Anesthesia · 2012 SCI
PROFESÖR OĞUZHAN ARUN →
Is a Neutral Head Position as Effective as Head Rotation During Landmark-Guided Internal Jugular Vein Cannulation? Results of a Randomized Controlled Clinical Trial
Journal of cardiothoracic and vascular anesthesia · 2012 SCI-Expanded
PROFESÖR JALE BENGİ ÇELİK →
Is a Neutral Head Position as Effective as Head Rotation During Landmark Guided Internal Jugular Vein Cannulation Results of a Randomized Controlled Clinical Trial
Journal of Cardiothoracic and Vascular Anesthesia · 2012 SCI-Expanded
PROFESÖR JALE BENGİ ÇELİK →

Makale Bilgileri

DergiJournal of Cardiothoracic and Vascular Anesthesia
Yayın TarihiAralık 2012
Cilt / Sayfa26 · 985-988
Özet Objective: Central venous access remains a cornerstone procedure for a variety of clinical conditions. Ultrasound studies suggest that rotation of the head increases the magnitude of the overlap of the internal jugular vein with the carotid artery. The authors assessed whether a neutral position of the head during anatomic landmark-guided cannulation of the internal jugular vein (IJV) was an attractive alternative to rotating the neck to a >45° head turn. Design: A prospective, randomized, controlled study. Setting: An education and research hospital and a university-affiliated hospital. Participants: Eighty patients requiring central venous catheterization in the right IJV. Interventions: Under general anesthesia, patients were positioned in the Trendelenburg position with extension of the neck. In the rotated group, the head was rotated to the left at >45°. In the neutral group, the head was placed in the neutral position. Right IJV cannulation was performed using the central approach with the needle angled toward the ipsilateral nipple. The primary outcome variable was the cumulative success rate, which was defined as IJV puncture achieved in the first 3 attempts using a finder needle. A p value of <0.05 was considered statistically significant. Measurements and Main Results: Groups were similar in terms of demographic data. The success rates of finder needle passes into the IJV on the first attempt were 87.5% and 37.5% (p < 0.05), and the cumulative success rates on the first 3 attempts were 97.5% and 57.5% in the rotated and neutral groups, respectively (p < 0.05). Carotid artery puncture only occurred in 2 patients in the rotated group. Conclusions: Because of the lower success rate, the neutral head position is not an attractive alternative for IJV catheterization when compared with the rotated head position in a central landmark IJV approach. © 2012 Elsevier Inc.

Yazarlar (6)

1
Burhan Apiliogullari
2
Inci Kara
3
Seza Apiliogullari
4
Oguzhan Arun
ORCID: 0000-0001-6101-1481
5
Ali Ozgul Saltali
6
Jale Çelik

Anahtar Kelimeler

Central venous access common carotid artery complications head position internal jugular vein

Kurumlar

Konya Education and Research Hospital
Konya Turkey
Selçuk Üniversitesi
Selçuklu Turkey

Metrikler

10
Atıf
6
Yazar
5
Anahtar Kelime

Sistemimizdeki Yazarlar