Scopus
🔓 Açık Erişim YÖKSİS Eşleşti
Diameter measurements and variations of the hepatic arterial system in multidetector computed tomography images
International Journal of Morphology · Haziran 2021
YÖKSİS Kayıtları
Diameter measurements and variations of the hepatic arterial system in multidetector computed tomography images
International Journal of Morphology · 2021 SCI-Expanded
PROFESÖR AHMET KAĞAN KARABULUT →
Diameter Measurements and Variations of the Hepatic Arterial System in Multidetector Computed Tomography Images
International Journal of Morphology · 2021 SCI-Expanded
PROFESÖR MUSTAFA KOPLAY →
Diameter Measurements and Variations of the Hepatic Arterial System in Multidetector Computed Tomography Images
International Journal of Morphology · 2021 SCI-Expanded
PROFESÖR NADİRE ÜNVER DOĞAN →
Diameter measurements and variations of the hepatic arterial system in multidetector computed tomography images
International Journal of Morphology · 2021 SCI-Expanded
PROFESÖR NADİRE ÜNVER DOĞAN →
Diameter measurements and variations of the hepatic arterial system in multidetector computed tomography images
International Journal of Morphology · 2021 SCI-Expanded
PROFESÖR ZELİHA FAZLIOĞULLARI →
Makale Bilgileri
DergiInternational Journal of Morphology
Yayın TarihiHaziran 2021
Cilt / Sayfa39 · 869-875
Scopus ID2-s2.0-85110695059
Erişim🔓 Açık Erişim
Özet
SUMMARY: Liver plays an important role in many events such as bile production, blood filtration and metabolic functions. The liver is supplied by the hepatic arterial system. The hepatic arterial system anatomy has a variable structure and the rate of variation is high. In our study, we aimed to determine the diameters and variation of the arteries supplying the liver with multidetector computed tomography images. In this study, hepatic arterial system variations of 500 cases whose abdominal region was imaged with multi-detector computed tomography were evaluated and the diameters of the related arteries were measured. The mean diameters of classical and variational anatomy were determined in this study. According to mean measurements of classical and variational anatomy were abdominal aorta 21.95 mm, celiac artery 7.2 mm, common hepatic artery 4.3 mm, proper hepatic artery 2.93 mm, right hepatic artery 2.92 mm, left hepatic artery 2.51 mm and abdominal aorta 21.85 mm, celiac artery 6.99 mm, common hepatic artery 5.07 mm, proper hepatic artery 3.83 mm, right hepatic artery 2.87 mm ve left hepatic artery 2.09 mm respectively. When evaluated in terms of variations, 85.6 % of the cases had branching according to Type I, 14.4 % of the cases had different branching patterns. Type III (87.5 %) was the most observed variation among them. As a result of the study, it was determined that the arterial diameters vary according to the state of variation and that the arterial diameter of men are greater than that of women.
Yazarlar (5)
1
Abdulkadir Bilir
ORCID: 0000-0003-0633-9542
2
Zeliha Fazliogullari
ORCID: 0000-0002-5103-090X
3
M. Koplay
ORCID: 0000-0001-7513-4968
4
Nadire Unver Dogan
5
Ahmet Kagan Karabulut
Anahtar Kelimeler
Arterial system
Liver
Multidetector computed tomography
Variation
Kurumlar
Afyonkarahisar Health Sciences University
Afyonkarahisar Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Metrikler
2
Atıf
5
Yazar
4
Anahtar Kelime