CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus 🔓 Açık Erişim YÖKSİS DOI Eşleşti SJR Q4

Which Modality Should Be Integrated to Increase the Diagnostic Efficiency of BI-RADS 0, 3, and 4 Lesions? Ultrasonography or Digital Breast Tomosynthesis?

Iranian Journal of Radiology · Ekim 2021

YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Which Modality Should Be Integrated to Increase the Diagnostic Efficiency of BI-RADS 0, 3, and 4 Lesions? Ultrasonography or Digital Breast Tomosynthesis?
Iranian Journal of Radiology · 2021 SCI-Expanded
Dr. Öğr. Üyesi MUSLU KAZIM KÖREZ →
YÖKSİS ISSN Eşleşmesi

Bu dergide (ISSN eşleşmesi) kurumun 12 kaydı bulundu.

YÖKSİS Kayıtları — ISSN Eşleşmesi
Evaluation of the Thyroid Parenchymal Stiffness During Pregnancy Using Two-Dimensional Shear Wave Elastography: A Longitudinal Prospective Study
2025 ISSN: 1735-1065 SCI-Expanded Q4
Prof. Dr. MUSTAFA KOPLAY →
Gangrenous Appendicitis in a Boy With Mobile Caecum
2015 ISSN: 1735-1065 SCI-Expanded
Prof. Dr. TAMER SEKMENLİ →
Gangrenous Appendicitis in a Boy With Mobile Caecum
2015 ISSN: 1735-1065 SCI-Expanded
Prof. Dr. METİN GÜNDÜZ →
Measuring the Effect of Filters on Segmentation of Developmental Dysplasia of the Hip
2016 ISSN: 1735-1065 SCI-Expanded
Prof. Dr. MUSTAFA KOPLAY →
Measuring the Effect of Filters on Segmentation of Developmental Dysplasia of the Hip
2016 ISSN: 1735-1065 SCI-Expanded
Prof. Dr. HASAN ERDİNÇ KOÇER →
Measuring the Effect of Filters on Segmentation of Developmental Dysplasia of the Hip
2016 ISSN: 1735-1065 SCI-Expanded
Prof. Dr. MUSTAFA KOPLAY →
Evaluation of a Healthy Pregnant Placenta with Shear Wave Elastography
2019 ISSN: 1735-1065 SCI
Dr. Öğr. Üyesi MUSLU KAZIM KÖREZ →
Evaluation of a Healthy Pregnant Placenta with Shear Wave Elastography
2019 ISSN: 1735-1065 SCI-Expanded Q4
Dr. Öğr. Üyesi MUSLU KAZIM KÖREZ →
Demonstration of Cephaloceles in Patients with Rhinorrhea: Single Center Experience of Intrathecal Gadolinium Enhanced MR Cisternography
2020 ISSN: 1735-1065 SCI-Expanded
Doç. Dr. HAKAN CEBECİ →
Evaluation of a Healthy Pregnant Placenta with ShearWaveElastography
2018 ISSN: 1735-1065 SCI
Dr. Öğr. Üyesi MUSLU KAZIM KÖREZ →
Is Digital Breast Tomosynthesis Superior to Digital Mammography? A Preclinical Evaluation of Tumor Histopathological Markers Using Digital Breast Tomosynthesis
2021 ISSN: 1735-1065 SCI-Expanded Q4
Dr. Öğr. Üyesi MUSLU KAZIM KÖREZ →
Which Modality Should Be Integrated to Increase the Diagnostic Efficiency of BI-RADS 0, 3, and 4 Lesions? Ultrasonography or Digital Breast Tomosynthesis?
2021 ISSN: 1735-1065 SCI-Expanded Q4
Dr. Öğr. Üyesi MUSLU KAZIM KÖREZ →

Makale Bilgileri

ISSN17351065
Yayın TarihiEkim 2021
Cilt / Sayfa18
Erişim🔓 Açık Erişim
Özet Background: Digital mammography (DM) is one of the most common and effective radiological methods for breast cancer screening and detection. A dense fibroglandular breast tissue can lead to false negative results by superimposing on the lesion margins. Therefore, adjunctive imaging methods, such as digital breast tomosynthesis (DBT) and ultrasonography (US), are needed to increase mammographic sensitivity. Objectives: This study aimed to examine the contribution of US and DBT to DM in different patient groups (patients group of breast imaging-reporting and data system [BIRADS] 0 and 3-4 lesions, patients with dense breast parenchyma, patients with non-dense breast parenchyma).. Whether US and DBT can upgrade or downgrade the BI-RADS category of uncertain lesions detected on DM was also investigated. Patients and Methods: Forty-six patients, who were classified as BI-RADS categories 0, 3, and 4 in DM, according to DBT and US findings, were included in the study. DM followed by DBT was performed for the patients, and the BI-RADS classification system was applied. Subsequently, the patients were evaluated sonographically, and the BI-RADS system was applied according to the US results. Each BI-RADS category was compared with the histopathological and multimodality follow-up results. The diagnostic performance of all modalities was also examined alone and in combination. Results: The sensitivity and specificity of DM alone was 42% and 87%, respectively. DBT detected the lesions with 92% sensitivity and 68% specificity. The modality with the highest sensitivity for the detection of malignant lesions was US (100%). Besides, the specificity of DBT was significantly high for dense breasts (P < 0.001). There was no significant difference in terms of the diagnostic accuracy of US measurements between dense and non-dense breasts. For indeterminate lesions, the integration of DBT and US to DM increased the diagnostic accuracy. Conclusion: The contribution of DBT is more valuable than US in patients with dense breast parenchyma.

Yazarlar (5)

1
Fatma Zeynep Arslan
2
Ayşegül Altunkeser
3
Nergis Aksoy
4
M. K. Korez
ORCID: 0000-0001-9524-6115
5
Ethem Omeroglu

Anahtar Kelimeler

Breast Cancer Digital Breast Tomosynthesis Digital Mammography Ultrasonography

Kurumlar

Basaksehir City Hospital
Istanbul Turkey
Selçuk Üniversitesi
Selçuklu Turkey
University of Health Sciences
Istanbul Turkey
Scimago Dergi (ISSN Eşleşmesi)
Iranian Journal of Radiology
Q4 OA
SJR Skoru0,150
H-Index25
YayıncıBrieflands
ÜlkeNetherlands
Radiology, Nuclear Medicine and Imaging (Q4)
Dergi sayfasına git

Metrikler

1
Atıf
5
Yazar
4
Anahtar Kelime