Scopus
YÖKSİS Eşleşti
The use of cooling holes to decrease the amount of thermal damage on a plastic gear tooth
Journal of Failure Analysis and Prevention · Ocak 2010
YÖKSİS Kayıtları
THE USE OF COOLING HOLES TO DECREASE THE AMOUNT OF THERMAL DAMAGE ON A PLASTIC GEAR TOOTH
Journal of Failure Analysis and Prevention · 2010 Emerging Sources Citation Index, SCOPUS, Google Scholar, ProQuest, EBSCO, EI Compendex
PROFESÖR HAYRETTİN DÜZCÜKOĞLU →
Makale Bilgileri
DergiJournal of Failure Analysis and Prevention
Yayın TarihiOcak 2010
Cilt / Sayfa10 · 545-555
Scopus ID2-s2.0-78649721339
Özet
A new method was developed to decrease the amount of thermal damage on the contact surface of a plastic gear tooth. The main aim of this method is to decrease the amount of thermal damage on the tooth surface by reducing the heat accumulated in the tooth under working conditions. For this reason, air-cooling holes on the plastic gear tooth were drilled in different locations, with the intention of lowering the tooth temperature by transferring the heat away from the tooth through these holes via convection. Using three the different configurations of holes, the air and temperature at the tooth contact zone were measured and compared. © 2010 ASM International.
Yazarlar (3)
1
Hayrettin Düzcükoğlu
2
R. Yakut
3
Eyyub Uysal
Anahtar Kelimeler
Durability
Frictional heating
Gear surface temperature
Plastic gears
Kurumlar
Hema Endüstri A.Ş. Çerkezköy
Tekirdag Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Metrikler
18
Atıf
3
Yazar
4
Anahtar Kelime