Scopus Eşleşmesi Bulundu
29
Cilt
419-425
Sayfa
🔓
Açık Erişim
Scopus Yazarları: Osman Vefa Gül, Hikmettin Demir, Taylan Tuğrul
Özet
The aim of this study is to measure out-of-field lens and thyroid doses in whole brain radiotherapy with thermoluminescence dosimeters (TLD) and compare them with treatment planning system (TPS) calculation values. Before Computed Tomography (CT), TLDs were placed on the lens and thyroid surfaces of the rando phantom and then the phantom was scanned with CT. Data was transferred from CT to RayStation™ TPSs and then target volume and critical organs were determined. The treatment plan was created. TLDs were placed on the lens es and thyroid for out-of-field dose measurement. For the right lens, the mean value of TLD measurements were 188.3±2.2 cGy and the mean values of TPS measurement were 192.0±0.2 cGy. The average TLD measurement for the left lens was 190.2±0.5 cGy, and the average TPS dose reading was 192.0±0.1 cGy. For doses in the thyroid region, which is further from the target, the TLD measurement and TPS reading averages were 44.9±5.2 cGy and 40.9±6.3 cGy, respectively. Accordingly, right lens point doses calculated from TPS were 1.93% higher than TLD measurements. For the left lens, this difference in the same direction was determined as 0.93%. Within the thyroid region, TLD measurements were observed to be higher than TPS readings. We measured out-of-field doses via TLDs and found that TPS calculations for thyroid were 8.90% lower than the measured dose. The results we obtained from our study are guiding in estimating out-of-field lens and thyroid doses in 3DCRT whole brain irradiation.
Anahtar Kelimeler (Scopus)
Lens
Thyroid
Out-of-Field
TLD
TPS
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2024 yılı verileri
Eastern Journal of Medicine
Q4
SJR Quartile
0,122
SJR Skoru
14
H-Index
🔓
Açık Erişim
Kategoriler: Medicine (miscellaneous) (Q4)
Alanlar: Medicine
Ülke: Turkey
· Yuzuncu Yil University
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
Radyoterapi
Lens
Thyroid
Out-of-Field
TLD
TPS
mavi = YÖKSİS
yeşil = Scopus
Makale Bilgileri
Dergi
Eastern Journal Of Medicine
ISSN
1301-0883
Yıl
2024
/ 10. ay
Cilt / Sayı
29
/ 4
Sayfalar
419 – 425
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
TR DİZİN
TEŞV Puanı
27,00
Yayın Dili
İngilizce
Kapsam
Ulusal
Toplam Yazar
3 kişi
Erişim Türü
Basılı+Elektronik
Erişim Linki
Makaleye Git
Alan
Sağlık Bilimleri Temel Alanı
Sağlık Fiziği
Radyoterapi
YÖKSİS Yazar Kaydı
Yazar Adı
DEMİR HİKMETTİN,GÜL OSMAN VEFA,TUĞRUL TAYLAN
YÖKSİS ID
8186990
Hızlı Erişim
Metrikler
TEŞV Puanı
27,00
Yazar Sayısı
3