CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q1 Özgün Makale Scopus
Evaluation of surface tensions and root-dentin surface contact angles of different endodontic irrigation solutions
BMC Oral Health 2024 Cilt 24
Scopus Eşleşmesi Bulundu
2
Atıf
24
Cilt
🔓
Açık Erişim
Scopus Yazarları: Hatice Buyukozer Ozkan, Arslan Terlemez, Ahmet Burcin Batibay, Hilal Erdogan, Funda Kont Cobankara
Özet
Background: Surface tension and contact angle properties, which play a crucial role in determining the effectiveness of irrigation solutions in penetrating dentin surfaces and dentin tubules, are highly important for the development of new irrigation solutions and their preferences. The aim of the current study was to compare the surface tension and contact angle properties of different irrigation solutions used in endodontics, both on the dentin surface and within dentin tubules. Methods: In this study, the contact angles and surface tensions of 5.25% sodium hypochlorite (NaOCl), 17% ethylenediaminetetraacetic acid (EDTA), 2% chlorhexidine (CHX), 5% boric acid (BA), 0.02% hypochlorous acid (HOCl), 0.2% chlorine dioxide (ClO2), Biopure MTAD, QMix solutions, and distilled water (control group) were measured. Measurements were conducted using a goniometer device (Attension Theta Lite Tensiometer, Biolin Scientific, USA), employing the sessile drop method for contact angle measurements on pre-prepared dentin surfaces, and the pendant drop method for surface tension. Results: Contact angle measurements revealed no statistically significant differences between the contact angle values of MTAD, ClO2, and CHX or between NaOCl, QMix, BA, and HOCl (p > 0.05). However, EDTA exhibited a significantly greater contact angle than did MTAD, ClO2, CHX, NaOCl, QMix, BA, and HOCl (p < 0.05). Furthermore, the contact angle of dentin with distilled water was greater than that with all other solutions tested (p < 0.05). Surface tension measurements revealed that the surface tension values of QMix and MTAD were statistically similar (p > 0.05). CHX exhibited lower surface tension than distilled water and HOCl (p < 0.05), and it also had lower surface tension than ClO2, NaOCl, and BA (p < 0.05). Additionally, the surface tension of the samples treated with EDTA was greater than that of all other solutions tested (p < 0.05). Conclusion: The direct linear relationship between the surface tension of liquids and contact angles on different surfaces may not always hold true, and these values should be considered independently for each solution on various surfaces. Considering the contact angles and surface tension properties of irrigation solutions with root canal dentin, it can be suggested for clinical use that ClO2 could be recommended over NaOCl, and similarly, BA could be recommended over EDTA.
Anahtar Kelimeler (Scopus)
Root canal dentin Surface tension Contact angle Irrigation solution

Anahtar Kelimeler

Root canal dentin Surface tension Contact angle Irrigation solution

Makale Bilgileri

Dergi BMC Oral Health
ISSN 1472-6831
Yıl 2024 / 6. ay
Cilt / Sayı 24
Sayfalar 681 – 691
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q1
TEŞV Puanı 288,00
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 5 kişi
Erişim Türü Basılı+Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı Endodonti

YÖKSİS Yazar Kaydı

Yazar Adı BÜYÜKÖZER ÖZKAN HATİCE,TERLEMEZ ARSLAN,BATIBAY AHMET BURÇİN,ERDOĞAN HİLAL,KONT ÇOBANKARA FUNDA
YÖKSİS ID 8062847

Metrikler

Scopus Atıf 2
JCR Quartile Q1
TEŞV Puanı 288,00
Yazar Sayısı 5