Scopus Eşleşmesi Bulundu
3
Atıf
163
Cilt
Scopus Yazarları: Ömer Faruk Topaloglu, M. Koplay, Abidin Kılınçer, Gökçen Örgül, Mehmet Sedat Durmaz
Özet
Purpose: Fetal cardiac magnetic resonance imaging (FCMR) can be used as an imaging modality in fetal cardiovascular evaluation as studied in recent years. We aimed to evaluate cardiovascular morphology using FCMR and to observe the development of cardiovascular structures according to gestational age (GA) in pregnant women. Method: In our prospective study, 120 pregnant women between 19 and 37 weeks of gestation in whom absence of cardiac anomaly could not be excluded by ultrasonography (US) or, who were referred to us for magnetic resonance imaging (MRI) for suspected non-cardiovascular system pathology, were included. According to the axis of the fetal heart, axial, coronal, and sagittal multiplanar steady-state free precession (SSFP) and 'real time' untriggered SSFP sequence, respectively, were obtained. The morphology of the cardiovascular structures and their relationships with each other were evaluated, and their sizes were measured. Results: Seven cases (6.3%) contained motion artefacts that did not allow the assessment and measurement of cardiovascular morphology, and three (2.9%) cases with cardiac pathology in the analysed images were excluded from the study. The study included a total of 100 cases. Cardiac chamber diameter, heart diameter, heart length, heart area, thoracic diameter, and thoracic area were measured in all fetuses. The diameters of the aorta ascendens (Aa), aortic isthmus (Ai), aorta descendens (Ad), main pulmonary artery (MPA), ductus arteriosus (DA, superior vena cava (SVC), and inferior vena cava (IVC) were measured in all fetuses. The left pulmonary artery (LPA) was visualised in 89 patients (89%). The right PA (RPA) was visualised in 99 (99%) cases. Four pulmonary veins (PVs) were seen in 49 (49%) cases, three in 33 (33%), and two in 18 (18%). High correlation values were found for all diameter measurements performed with GW. Conclusion: In cases where US cannot achieve adequate image quality, FCMR can contribute to diagnosis. The very short acquisition time and parallel imaging technique with the SSFP sequence allow for adequate image quality without maternal or fetal sedation.
Anahtar Kelimeler (Scopus)
Ultrasonography
Cardiac MRI
Fetal imaging
Magnetic resonance
SSFP
Anahtar Kelimeler
Ultrasonography
Cardiac MRI
Fetal imaging
Magnetic resonance
SSFP
Makale Bilgileri
Dergi
European Journal of Radiology
ISSN
0720-048X
Yıl
2023
/ 6. ay
Cilt / Sayı
163
/ 110828
Sayfalar
1 – 9
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
JCR Quartile
Q2
TEŞV Puanı
288,00
Yayın Dili
Türkçe
Kapsam
Uluslararası
Toplam Yazar
5 kişi
Erişim Türü
Basılı+Elektronik
Erişim Linki
Makaleye Git
Alan
Sağlık Bilimleri Temel Alanı
Radyoloji
YÖKSİS Yazar Kaydı
Yazar Adı
TOPALOĞLU ÖMER FARUK, KOPLAY MUSTAFA, KILINÇER ABİDİN, ÖRGÜL GÖKÇEN, DURMAZ MEHMET SEDAT
YÖKSİS ID
7269242
Hızlı Erişim
Metrikler
Scopus Atıf
3
JCR Quartile
Q2
TEŞV Puanı
288,00
Yazar Sayısı
5