CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q3 Özgün Makale Scopus
Evaluation of refractometry methods for estimating passive immunity status in neonatal foals.
Journal of Immunological Methods 2022 Cilt 510
Scopus Eşleşmesi Bulundu
3
Atıf
510
Cilt
Scopus Yazarları: Mehmet Akköse, Eren Karabulut, Çağdaş Dik, Mustafa Çam, Ceyhan Özbeyaz, Durmuş Orakçı, Murat Durmaz, İsmail Yılmaz, Şeref Inal, Elif Merve Çınar
Özet
The objective of this cross-sectional study was to determine the accuracy of the digital Brix and serum total protein (TP) refractometers for estimating different passive immunity status in neonatal foals. In total, 18- to 40-h old purebred Arabian foals (n = 185) were used. Serum TP concentrations, total solid percentages and IgG concentrations were measured with a digital serum TP refractometer, digital Brix refractometer and the gold standard radial immunodiffusion (RID) assay, respectively. Correlation coefficients were calculated between the refractometer and RID assay results. A receiver operating characteristic analysis was used to select the optimal cut-offs for both refractometers. Test performance and agreement were evaluated using diagnostic test characteristics at optimal thresholds and areas under the ROC curve, and by calculating Cohen's kappa coefficient. The sensitivity and specificity of the digital Brix refractometer at optimal cut-offs (≤7.8%, ≤7.9%, ≤8.2%, ≤8.3%, ≤9.0%) were 100 and 69.3%; 100% and 68.5%; 70.5% and 71.0%; 88.3% and 85.5%; 88.1% and 76% to estimate RID-IgG of <400 mg/dL, <800 mg/dL, <1500 mg/dL, <2500 mg/dL and < 3000 mg/dL, respectively. The sensitivity and specificity of the digital serum TP refractometer at optimal cut-off (≤4.6 g/dL, ≤4.6 g/dL, ≤4.8 g/dL, ≤5.0 g/dL, ≤5.4 g/dL) were 100 and 69.3%; 100% and 72.8%; 90% and 72.8%; 72.9% and 83.9%; 84.4% and 88% to estimate RID-IgG of <400 mg/dL, <800 mg/dL, <1500 mg/dL, <2500 mg/dL and < 3000 mg/dL, respectively. In conclusion, the refractometers showed a good potential as screening tools for the estimation of different IgG concentrations in neonatal foals.
Anahtar Kelimeler (Scopus)
Arabian foal Brix Failure of transfer of passive immunity Serum total protein Refractometer

Anahtar Kelimeler

Arabian foal Brix Failure of transfer of passive immunity Serum total protein Refractometer

Makale Bilgileri

Dergi Journal of Immunological Methods
ISSN 0022-1759
Yıl 2022 / 9. ay
Cilt / Sayı 510
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q3
TEŞV Puanı 9,00
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 10 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı İmmünoloji ve Alerji Hastalıkları

YÖKSİS Yazar Kaydı

Yazar Adı AKKÖSE MEHMET, KARABULUT EREN, YILMAZ İSMAİL Ç, DİK Gürcan Çağdaş, İNAL ŞEREF, ÖZBEYAZ CEYHAN, ÇAM MUSTAFA, ÇINAR ELİF MERVE, ORAKÇI DURMUŞ, DURMAZ MURAT
YÖKSİS ID 6520616

Metrikler

Scopus Atıf 3
JCR Quartile Q3
TEŞV Puanı 9,00
Yazar Sayısı 10