CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q4 Özgün Makale Scopus
Diagnostic value of CRP and Lp(a) in coronary heart disease
ACTA CARDIOLOGICA 2002 Cilt 57 Sayı 3
Scopus Eşleşmesi Bulundu
42
Atıf
57
Cilt
197-204
Sayfa
Scopus Yazarları: Mehmet Tarakçioglu, Mehmet Aksoy, Cumhur Sivrikoz, Ayse Binnur Erbagci, Ramazan Kocabaş, Muradiye Nacak, A. Şükrü Aynacioǧlu
Özet
Objectives - Increased lipoprotein (a) [Lp(a)] concentration was reported to be an independent risk factor for coronary heart disease (CHD). Recent epidemiological studies affirmed the value of C-reactive protein (CRP) as the strongest, univariate predictor of the cardiovascular events. We decided to establish cut-off levels providing maximum diagnostic efficiency for CHD. Methods - In this study we measured CRP and Lp(a) concentrations in patients with angiographically demonstrated CHD (group A, n: 120), patients without any angiographically demonstrable lesion (group B, n: 62) and a group of healthy subjects (group C, n: 41). Data were evaluated correcting for lipid and lipoprotein concentrations, diabetes mellitus, hypertension, smoking, age, and body mass index in men and women. ROC curve based cut-off values (comparing group A versus groups B and C) and associated diagnostic performances of the assays were evaluated. Results - Significant increases were noted in serum CRP concentrations in men and women, in groups A vs. B, A vs. C, B vs. C. Lp(a) concentrations were not different among groups in men but were higher in group A vs. B and C in women. Optimal cut-off levels for CRP in women and men were found as 2.1 and 3.0 mg/l with the diagnostic values of 0.792 and 0.770, respectively. For Lp(a) optimal cut-off levels were found as 22.6 and 9.8 mg/dl with the diagnostic values of 0.612 and 0.596 in women and men, respectively. Conclusion - The CRP level is quite efficient for separation of patients from controls. Therefore keeping in mind the lack of specificity, the CRP level may be a useful tool in the diagnosis of coronary heart disease. However, the Lp(a) level is not efficient enough to support the use of Lp(a) measurement for management of coronary heart disease.
Anahtar Kelimeler (Scopus)
C-reactive protein Coronary heart disease Cut-off value Diagnostic efficiency Lipoprotein (a)

Anahtar Kelimeler

C-reactive protein Coronary heart disease Cut-off value Diagnostic efficiency Lipoprotein (a)

Makale Bilgileri

Dergi ACTA CARDIOLOGICA
ISSN 0001-5385
Yıl 2002 / 6. ay
Cilt / Sayı 57 / 3
Sayfalar 197 – 204
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q4
YÖKSİS Atıf 37
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 7 kişi
Erişim Türü Basılı+Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı- Tıbbi Biyokimya

YÖKSİS Yazar Kaydı

Yazar Adı ERBAĞCI AYŞE BİNNUR,TARAKÇIOĞLU MEHMET,AKSOY MEHMET,KOCABAŞ RAMAZAN,NACAK MURADİYE,AYNACIOĞLU AHMET ŞÜKRÜ,SİVRİKOZ CUMHUR
YÖKSİS ID 1604018

Metrikler

YÖKSİS Atıf 37
Scopus Atıf 42
JCR Quartile Q4
Yazar Sayısı 7