CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q2 Özgün Makale Scopus
Shear strengthening of reinforced concrete T-beams with anchored and non-anchored CFRP fabrics
Structures 2022 Cilt 39
Scopus Eşleşmesi Bulundu
80
Atıf
39
Cilt
527-542
Sayfa
Scopus Yazarları: Ceyhun Aksoylu, Musa Hakan Arslan, Şakir Yazman, Ahmed Abed Hamad, Yasin Onuralp Özkılıç, Lokman Gemi
Özet
Strengthening of shear deficient T-beams is not as easy as rectangular beams due to the presence of slabs. In this study, externally bonded reinforcement (EBR) such type of reinforced concrete shear deficient T-beams with and without anchorage in different CFRP configurations was experimentally and analytically investigated. Pursuant to this goal, nine half-scale T-beams were produced and tested with monotonic loading under four points. Seven of these T-beams are strengthened with partial CFRP strip and one is strengthened with full CFRP wrapped in the shear span. The failures of strengthened beams are initiated with the debonding failure of FRP sheets followed by brittle shear failure. In order to prevent this failure, two specimens with partial CFRP strip are fixed to the beam by using anchors at different angles of 45° and 90°. The experimental results indicated that the contribution of EBR to the shear capacity is significant and depends on different variables such as anchorage angle, strengthening type. Moreover, the strengthening method that gives the most effective results in strengthening T-beams are full wrapping CFRP and partial CFRP with a 45-degree anchorage type. The anchorage application increased the shear capacity by 42.6%∼53.8% compared to the reference specimens. In addition, the anchors with angle of 45° increased stiffness by 37%. In terms of ductility, the best result was given by the type of strengthening where the slabs were broken and the beam was completely wrapped. This method contributed 42%∼80% more to ductility than other methods. The obtained experimental results were also compared with the empirical correlations given by ACI 440.2R-17, TBEC-2019 and FIB-2010 and recommendations are given. Especially in fully wrapped beams, the estimation of ACI was determined to be 96%. The estimations of the other codes are far from meeting the experimental results; therefore, essential improvements should be applied to the codes, especially with regard to CFRP deformation and approaches for anchored connections.
Anahtar Kelimeler (Scopus)
Analytical analysis Anchorage Building Codes CFRP Damage analysis Reinforced Concrete T-beams Strengthening

Anahtar Kelimeler

Analytical analysis Anchorage Building Codes CFRP Damage analysis Reinforced Concrete T-beams Strengthening

Makale Bilgileri

Dergi Structures
ISSN 2352-0124
Yıl 2022 / 5. ay
Cilt / Sayı 39
Sayfalar 1527 – 542
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q2
TEŞV Puanı 24,00
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 6 kişi
Erişim Türü Basılı+Elektronik
Erişim Linki Makaleye Git
Alan Mühendislik Temel Alanı Makine Mühendisliği Malzeme Tasarım ve Davranışları Kompozit Malzemeler Nanoteknoloji

YÖKSİS Yazar Kaydı

Yazar Adı ARSLAN MUSA HAKAN, YAZMAN ŞAKİR, Abed Hamad Ahmed, AKSOYLU CEYHUN, ÖZKILIÇ YASİN ONURALP, GEMİ LOKMAN
YÖKSİS ID 6227454

Metrikler

Scopus Atıf 80
JCR Quartile Q2
TEŞV Puanı 24,00
Yazar Sayısı 6