Developing a robust, fast and reliable measurement method for the analysis of methylarginine derivatives and related metabolites
Journal of Mass Spectrometry and Advances in the Clinical Lab 2021 Cilt 19 Sayı 1
Scopus Eşleşmesi Bulundu
4
Atıf
19
Cilt
34-45
Sayfa
🔓
Açık Erişim
Scopus Yazarları: Duygu Eryavuz Onmaz, Sedat Abusoglu, Havva Yaglioglu, Gulsum Abusoglu, Ali Ünlü
Özet
Background: Nitric oxide (NO) plays an important role in endothelial homeostasis. Asymmetric dimethyl arginine (ADMA), L-N monomethyl arginine (L-NMMA) and symmetric dimethyl arginine (SDMA), which are derivatives of methylarginine, directly or indirectly reduce NO production. Therefore, these metabolites are an important risk factor for various diseases, including cardiovascular diseases. Numerous methods have been developed for the measurement of methylarginine derivatives, but various difficulties have been encountered. This study aimed to develop a reliable, fast and cost-effective method for the analysis and measurement of methylarginine derivatives (ADMA, SDMA, L-NMMA) and related metabolites (arginine, citrulline, homoarginine, ornithine), and to validate this method according to Clinical and Laboratory Standards Institute (CLSI) protocols. Methods: For the analysis of ADMA, SDMA, L-NMMA, arginine, homoarginine, citrulline, ornithine, 200 µl of serum were precipitated with methanol, and subsequently derivatized with a butanol solution containing 5% acetyl chloride. Butyl derivatives were separated using a C18 reverse phase column with a 5 min run time. Detection of analytes was achieved by utilising the specific fragmentation patterns identified through tandem mass spectrometry. Results: The method was linear for ADMA, SDMA, L-NMMA, ornithine, arginine, homoarginine and citrulline in the ranges of 0.023–6.0, 0.021–5.5, 0.019–5.0, 0.015–250, 0.015–250, 0.019–5 and 0.015–250 µM, respectively. The inter-assay CV% values for all analytes was less than 9.8%. Conclusions: Data obtained from method validation studies shows that the developed method is highly sensitive, precise and accurate. Short analysis time, cost-effectiveness, and multiplexed analysis of these metabolites, with the same pretreatment steps, are the main advantages of the method.
Anahtar Kelimeler (Scopus)
ADMA Methylarginines Tandem mass spectrometry Validation

Anahtar Kelimeler

ADMA Methylarginines Tandem mass spectrometry Validation

Makale Bilgileri

Dergi Journal of Mass Spectrometry and Advances in the Clinical Lab
ISSN 2667-145X
Yıl 2021 / 1. ay
Cilt / Sayı 19 / 1
Sayfalar 34 – 45
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q3
TEŞV Puanı 18,00
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 5 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı Tıbbi Biyokimya

YÖKSİS Yazar Kaydı

Yazar Adı ERYAVUZ ONMAZ DUYGU, ABUŞOĞLU SEDAT, Yağlıoğlu Havva, ABUŞOĞLU GÜLSÜM, ÜNLÜ ALİ
YÖKSİS ID 6107588

Metrikler

Scopus Atıf 4
JCR Quartile Q3
TEŞV Puanı 18,00
Yazar Sayısı 5