Özdeş İki Spektrofotometrenin Cihazlar Arası Güvenilirlik Ve Tekrarlanabilirliğinin İncelenmesi
Selcuk Dental Journal 2021 Cilt 8 Sayı 3
Scopus Eşleşmesi Bulundu
8
Cilt
605-610
Sayfa
🔓
Açık Erişim
Scopus Yazarları: Tuba Yilmaz-Savas, Abdulhaluk Savaş, Ali Riza Tunçdemir
Özet
Background: The purpose of this in-vitro study was to evaluate the repeatability and interdevice reliability of two identical spectrophotometers with different software. Methods: Twenty-six shade tabs of a shade guide (Vita 3D-Master, Vita Zahnfabrik) were measured with two identical spectrophotometers (Vita EasyShade V) with different software (v509i: Device A; v505p: Device B), and CIELab values were recorded (n=260). The color difference (∆E<inf>00</inf>) values between measurements of spectrophotometers were calculated. For repeatability, the 3M2 shade tab of the same shade guide was measured 50 times with each spectrophotometer. The matching accuracy rate of the devices with shade guide was calculated. Interdevice reliability and differences between devices were calculated using intraclass correlation coefficient (ICC), Cronbach's alpha, and Paired T-test (α=0.05). Results: Interdevice reliability was found to be high for L*, a*, and b* parameters (ICC>0.99). The ∆E<inf>00</inf> values of the shade tabs range from 0.21 to 1.78, which were lower than the acceptability threshold (∆E<inf>00</inf><1.8). The mean L* value of Device A was significantly higher than that of Device B (P<0.001), while the mean a* and b* values were significantly lower (P<0.001). The repeatability is excellent for a* and b* parameters (SD<0.1), however, slightly lower for the L* (0.15<SD<0.25) in both devices. The matching accuracy rates of both devices were calculated as 34.6 %. Conclusion: The reliability and repeatability of two identical spectrophotometers were found to be high, and the color difference values were found to be at an acceptable level. However, both devices can display different L*, a*, and b* values for the same shade guide.
Anahtar Kelimeler (Scopus)
Color Equipment failure analysis Reliability Repeatability Spectrophotometry

Anahtar Kelimeler

Color Equipment failure analysis Reliability Repeatability Spectrophotometry

Makale Bilgileri

Dergi Selcuk Dental Journal
ISSN 2148-7529
Yıl 2021 / 12. ay
Cilt / Sayı 8 / 3
Sayfalar 605 – 610
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks TR DİZİN
TEŞV Puanı 27,00
Yayın Dili Türkçe
Kapsam Ulusal
Toplam Yazar 3 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı Protetik Diş Tedavisi

YÖKSİS Yazar Kaydı

Yazar Adı YILMAZ SAVAŞ TUBA, SAVAŞ ABDULHALUK, TUNÇDEMİR ALİ RIZA
YÖKSİS ID 6055675

Metrikler

TEŞV Puanı 27,00
Yazar Sayısı 3