Scopus Eşleşmesi Bulundu
6
Atıf
51
Cilt
972-980
Sayfa
🔓
Açık Erişim
Scopus Yazarları: Nazlım Aktuğ Demir, Abdussamed Batur, Recai Ergün, Abidin Kılınçer, Fatih Ates
Özet
Background/aim: To investigate the changes in the spleen size, parenchymal heterogeneity, and computed tomography (CT) texture analysis features of patients diagnosed with Coronavirus disease 2019 (COVID-19) Materials and methods: The size and parenchymal structure of the spleen in 91 patients who underwent thoracic CT examination due to COVID-19 were evaluated. For the evaluation of parenchymal heterogeneity, CT texture analysis was performed using dedicated software (Olea Medical, France). The texture analysis of each case consisted of 15 first-order intensity-based features, 17 gray level co-occurrence matrix-based features, and 9 gray level run length matrix-based features. Results: A total of 91 patients (45 males, 46 females) with a mean age of 54.31 ± 16.33 years (range: 18–81) were included in the study. A statistically significant decrease in spleen size was seen in the follow-up CT examinations (p < 0.001) whereas no statistically significant difference was found between the Hounsfield unit (HU) values. The radiomics consisted of first-order intensity-based features such as 90th percentile, maximum, interquartile range, range, mean absolute deviation, standard deviation, and variance, all of which showed statistically significant differences (p-values: < 0.001, < 0.001, 0.001, 0.003, 0.001, 0.001, and 0.004, respectively). “Correlation” as a gray level co-occurrence matrix-based feature and “gray level nonuniformity” as a gray level run length matrix-based feature showed statistically differences (p-values: 0.033 and < 0.001, respectively). Conclusions: Although COVID-19 manifests with lung involvement in the early stage, it can also cause systemic involvement, and the spleen may be one of its target organs. A decrease in the spleen size and parenchymal microstructure changes can be observed in the short follow-up time. It is hoped that the changes in the parenchymal microstructure will be demonstrated by a noninvasive method: texture analysis.
Anahtar Kelimeler (Scopus)
Texture analysis
COVID-19
Spleen size
Anahtar Kelimeler
Texture analysis
COVID-19
Spleen size
Makale Bilgileri
Dergi
TURKISH JOURNAL OF MEDICAL SCIENCES
ISSN
1303-6165
Yıl
2021
/ 1. ay
Cilt / Sayı
51
/ 3
Sayfalar
972 – 980
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
JCR Quartile
Q3
TEŞV Puanı
18,00
Yayın Dili
Türkçe
Kapsam
Uluslararası
Toplam Yazar
5 kişi
Erişim Türü
Elektronik
Erişim Linki
Makaleye Git
Alan
Sağlık Bilimleri Temel Alanı
TIP
YÖKSİS Yazar Kaydı
Yazar Adı
BATUR ABDUSSAMET, KILINÇER ABİDİN, ATEŞ FATİH, AKTUĞ DEMİR NAZLIM, ERGÜN RECAİ
YÖKSİS ID
5284399
Hızlı Erişim
Metrikler
Scopus Atıf
6
JCR Quartile
Q3
TEŞV Puanı
18,00
Yazar Sayısı
5