CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Optimal Angle of Needle Entry for Internal Jugular Vein Catheterization with a Neutral Head Position: A CT Study
Renal Failure 2013 Cilt 35 Sayı 4
Scopus Eşleşmesi Bulundu
9
Atıf
35
Cilt
492-496
Sayfa
Scopus Yazarları: Seza Apiliogullari, Inci Kara, Emine Uysal, S. Ozbek, Cengiz Erol, Ali Sami Kivrak, M. Koplay, Ates Duman
Özet
Purpose: The aim of this study is to determine the optimal angle of needle entry in the sagittal plane for internal jugular vein (IJV) catheterization with the central approach while the head is in the neutral position. Methods: The contrast-enhanced carotid artery computed tomography angiographies of 123 consecutive patients were retrospectively reviewed. The point of merger between the sternal and clavicular heads of the sternocleidomastoid muscle was assumed as a clinical entry (CE) point. The angle between CE point and the center of the IJV, the depth, diameter of the vessels and the degree of overlap between the IJV and carotid artery (CA) were measured. Results: The angles between the CE point and the center of the IJVs were similar, 7° ± 13° medial and 8° ± 12° medial on the right and the left side, respectively. The center of IJVs from the CE point was between 0° and 16° toward the medial in 79.8% on the right side and 89.9% on the left side of patients. The diameters of the right IJVs were greater than the left IJVs (p = 0.001). The depth from the skin and overlap between IJV and CA did not vary between the two sides. Conclusions: When a central approach is used for right internal jugular vein (RIJV) cannulation with a neutral head position, the orientation of the angle of needle entry (i.e., 16°) medially in the sagittal plane may quadruple the success rate of RIJV catheterization compared to the success rate of a laterally oriented angle of entry as recommended by the classic method. Copyrigh © Informa Healthcare USA, Inc.
Anahtar Kelimeler (Scopus)
Jugular vein Neutral position entry angle Catheterization Computerized tomography (CT)
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2013 yılı verileri
Renal Failure
Q2
SJR Quartile
0,446
SJR Skoru
69
H-Index
🔓
Açık Erişim
Kategoriler: Critical Care and Intensive Care Medicine (Q2) · Medicine (miscellaneous) (Q2) · Nephrology (Q3)
Alanlar: Medicine
Ülke: United Kingdom · Informa Healthcare
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

Jugular vein Neutral position entry angle Catheterization Computerized tomography (CT)

Makale Bilgileri

Dergi Renal Failure
ISSN 0886-022X
Yıl 2013 / 2. ay
Cilt / Sayı 35 / 4
Sayfalar 492 – 496
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 8 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı- Radyoloji

YÖKSİS Yazar Kaydı

Yazar Adı Ozbek Seda,Apiliogullari Seza,EROL CENGİZ,Kivrak Ali Sami,KARA İNCİ,UYSAL EMİNE,KOPLAY MUSTAFA,DUMAN ATEŞ
YÖKSİS ID 4449855