CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q2 Özgün Makale Scopus
The relationship between serum clozapine concentrations and hematological parameters by a validated mass spectrometric method
Journal of Pharmaceutical and Biomedical Analysis 2020 Cilt 180 Sayı 4
Scopus Eşleşmesi Bulundu
6
Atıf
180
Cilt
Scopus Yazarları: Oguzhan Tok, Ali Ünlü, Karam Mazin Kamil Gharab, Duygu Eryavuz Onmaz, Sedat Abusoglu, Memduha Aydin, Abdullah Sivrikaya, Gulsum Abusoglu
Özet
Objective: Clozapine is one of the most effective drugs for resistant schizophrenia, but its severe metabolic and hematological side effects limit the use of clozapine. It has been reported that clozapine blood concentrations should be maintained between 350−600 ng/mL. Our aim was to develop a determination method for clozapine and its main metabolites norclozapine and clozapine-N-oxide, to perform validation studies and to investigate the change of various biochemical parameters in patients using clozapine. Methods: A liquid chromatography-tandem mass spectrometry (LC–MS/MS) method was developed and validated for clozapine measurement. Thus, blood samples were collected from 38 patients with schizophrenia and 32 healthy volunteers. Biochemical and hematological parameters were measured by Beckman-Coulter AU 5800 (Beckman Coulter, Brea, USA) and Beckman Coulter LH 780 analyzer (Beckman Coulter, Miami, FL, USA), respectively. Hormone levels were analyzed using Cobas 6000 analyzer (Roche Diagnostics, Germany). Results: The LC[sbnd]MS/MS method was linear between 1.22−2500 ng/mL (r2 = 0.9971) for clozapine. The retention times of clozapine, norclozapine and clozapine-N-oxide were 0.92, 0.89 and 0.95, respectively. Blood glucose (GLU) (p = 0.025), low density lipoprotein (LDL-cholesterol) (p = 0.015), triglyseride (TG) (p = 0.042) and total cholesterol (TC) (p = 0.024) levels were higher; hemoglobin (HGB) (0.015), mean corpuscular hemoglobin (MCH) (0.036), red blood cell count (RBC) (0.020), neutrophil (NEU) (0.034), and platelet (PLT) (P = 0.005) levels were lower in the clozapine group. Conclusions: This LC–MS/MS method was rapid, simple, cost-effective and suitable for the routine clozapine monitoring. Furthermore, norclozapine and clozapine-N-oxide were also determined. Monitoring of metabolic and hematological parameters with clozapine levels is very important. However, the limitations of the study were that the method was not validated for norclozapine and clozapine-N-oxide, so the validation parameters were not evaluated for these two metabolites.
Anahtar Kelimeler (Scopus)
Side effects Therapeutic drug monitoring Clozapine Tandem mass spectrometry

Anahtar Kelimeler

Therapeutic drug monitoring Tandem mass spectrometry Side effects Clozapine

Makale Bilgileri

Dergi Journal of Pharmaceutical and Biomedical Analysis
ISSN 0731-7085
Yıl 2020 / 2. ay
Cilt / Sayı 180 / 4
Sayfalar 113056 – 113056
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q2
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 8 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı Tıbbi Biyokimya

YÖKSİS Yazar Kaydı

Yazar Adı Gharab Karam Mazin Kamil, ERYAVUZ ONMAZ DUYGU, Abusoglu Sedat, Aydin Memduha, Sivrikaya Abdullah, Tok Oguzhan, Abusoglu Gulsum, Unlu Ali
YÖKSİS ID 4431434

Metrikler

Scopus Atıf 6
JCR Quartile Q2
Yazar Sayısı 8