CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Magnetic resonance enterography with oral mannitol solution: Diagnostic efficacy and image quality in Crohn disease
Diagnostic and Interventional Imaging 2017 Cilt 98 Sayı 12
Scopus Eşleşmesi Bulundu
11
Atıf
98
Cilt
893-899
Sayfa
🔓
Açık Erişim
Scopus Yazarları: Hakan Cebeci, Halil Haldun Emiroğlu, Y. Paksoy, Serkan Guneyli, Huseyin Korkmaz, Tamer Sekmenli, M. Koplay
Özet
Purpose The aim of this study was to investigate the diagnostic efficacy and image quality of magnetic resonance enterography (MRE) using oral mannitol solution for the evaluation Crohn disease (CD). Materials and methods We retrospectively evaluated MRE examinations of 153 patients with an assumed or definitive diagnosis of CD. There were 65 men and 88 women, with a mean age of 35.7 years (range: 6–73 years). MRE findings of the patients were compared to histopathologic results obtained by surgery-fiberoptic endoscopy. The sensitivity, specificity and diagnostic efficacy rate were calculated. Additionally, image quality of MRE was evaluated using a four-point scale (1 = excellent, 4 = poor/non-diagnostic). Results Sensitivity, specificity and diagnostic efficacy were 92.5%, 93% and 92.8%, respectively. Six patients had false-positive and five patients had false-negative findings. Three falsely positive patients had ulcerative colitis and three had non-specific terminal ileitis. A total of 765 small bowel segments were analyzed; 475 (62%) had an image quality score of 1 and 15 (2%), an image quality score of 4. Conclusion MRE using oral mannitol solution provides excellent image quality for MRE and has high degrees of diagnostic efficacy in CD patients.
Anahtar Kelimeler (Scopus)
Crohn disease Inflammatory bowel disease Mannitol MR-enterography Small bowel
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2017 yılı verileri
Diagnostic and Interventional Imaging
Q2
SJR Quartile
0,552
SJR Skoru
63
H-Index
🔓
Açık Erişim
Kategoriler: Medicine (miscellaneous) (Q2) · Radiological and Ultrasound Technology (Q2) · Radiology, Nuclear Medicine and Imaging (Q2)
Alanlar: Health Professions · Medicine
Ülke: France · Elsevier Masson s.r.l.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

Crohn disease Inflammatory bowel disease Mannitol MR-enterography Small bowel

Makale Bilgileri

Dergi Diagnostic and Interventional Imaging
ISSN 22115684
Yıl 2017 / 12. ay
Cilt / Sayı 98 / 12
Sayfalar 893 – 899
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 7 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı- Radyoloji

YÖKSİS Yazar Kaydı

Yazar Adı KOPLAY MUSTAFA,GÜNEYLİ SERKAN,CEBECİ HAKAN,KORKMAZ HÜSEYİN,EMİROĞLU HALİL HALDUN,SEKMENLİ TAMER,PAKSOY YAHYA
YÖKSİS ID 2596931