CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Increased left atrial pressure predicts recurrence following successful cryoablation for atrial fibrillation with second generation cryoballoon
Journal of Interventional Cardiac Electrophysiology 2016 Cilt 46 Sayı 2
Scopus Eşleşmesi Bulundu
22
Atıf
46
Cilt
145-151
Sayfa
Scopus Yazarları: Duygu Kocyigit, Kadri Murat Gurses, Muhammed Ulvi Yalçın, Mehmet Levent Şahiner, Ergün Barış Kaya, Necla Ozer, Banu Evranos, Kudret Aytemir
Özet
Purpose: Several studies have demonstrated that left ventricular diastolic dysfunction (LVDD) and left atrial pressure (LAP), as a surrogate marker of LVDD, were associated with atrial fibrillation (AF) recurrence following radiofrequency catheter ablation (RFCA) for AF. In this study, we aimed to investigate the individual impact of several left ventricular diastolic function parameters on outcomes of cryoablation for paroxysmal AF using second-generation cryoballoon. Methods: One hundred seventy patients who were scheduled for cryoablation with second-generation cryoballoon were included in this prospective study. All patients underwent comprehensive transthoracic and transesophageal echocardiographic examinations during sinus rhythm a day before catheter ablation. LAP was measured via transseptal sheath at the beginning of the ablation procedure. Results: One hundred seventy patients (57.09 ± 11.80 years, 47.06 % male) were involved in the study. At a median follow-up of 19 months, when blanking period of 3 months was considered, freedom from AF after a single ablation procedure was 84.71 %. Patients with AF recurrence had significantly greater left atrial volume index (LAVI) (p = 0.005) and LAP (p < 0.001). Patients with AF recurrence had lower septal eʹ wave (p = 0.013), and higher E/eʹ ratio (p = 0.014). LAVI (p = 0.007) and LAP (p = 0.006) were independent predictors of AF recurrence. A cut-off value of 13.50 mmHg for LAP measured during the procedure was associated with a sensitivity and specificity of 80.8 and 84.7 % (p = 0.005) for predicting AF recurrence. Conclusions: Pre-procedural LAVI and procedural LAP measurement have clinical importance in predicting AF recurrence in patients undergoing cryoablation with second-generation cryoballoon. Effectiveness of cryoablation is reduced in patients with greater LAVI and LAP.
Anahtar Kelimeler (Scopus)
Ablation Atrial fibrillation Diastolic functions Echocardiography Left atrial pressure
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2016 yılı verileri
Journal of Interventional Cardiac Electrophysiology
Q1
SJR Quartile
0,975
SJR Skoru
66
H-Index
Kategoriler: Medicine (miscellaneous) (Q1) · Cardiology and Cardiovascular Medicine (Q2) · Physiology (medical) (Q2)
Alanlar: Medicine
Ülke: United States · Springer
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

Ablation Atrial fibrillation Diastolic functions Echocardiography Left atrial pressure

Makale Bilgileri

Dergi Journal of Interventional Cardiac Electrophysiology
ISSN 1383-875X
Yıl 2016 / 8. ay
Cilt / Sayı 46 / 2
Sayfalar 145 – 151
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
TEŞV Puanı 126,00
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 8 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı- Kardiyoloji

YÖKSİS Yazar Kaydı

Yazar Adı EVRANOS BANU,KOÇYİĞİT DUYGU,Gurses Kadri Murat,YALÇIN MUHAMMED ULVİ,ŞAHİNER MEHMET LEVENT,KAYA ERGÜN BARIŞ,ÖZER NECLA,AYTEMİR KUDRET
YÖKSİS ID 2258380

Metrikler

Scopus Atıf 22
TEŞV Puanı 126,00
Yazar Sayısı 8