CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q3 Özgün Makale Scopus
Shear bond strength to enamel and failure type of different periodontal splints :in vivo and in vitro study
Journal of Adhesion Science and Technology 2016 Cilt 31 Sayı 12
Scopus Eşleşmesi Bulundu
31
Cilt
1374-1385
Sayfa
Scopus Yazarları: Merve Yıldız, Nimet Ünlü, Said Karabekiroğlu, Elif Öncü
Özet
The goal of this study was to evaluate the shear bond strength (SBS) and failure mode of four different splint materials [Polyethylene FRC Ribbond Thm (RB), Polyethylene FRC Construct (Kerr), Multifilament Fishing Line (MFL), and Non Fiber Reinforced Composite (control)]. Thirty-seven subjects were randomly divided into four splint methods. After splinting procedures, the subjects were recalled 12 months later. One hundred and sixty human mandibular incisors (for extracoronal and intracoronal splinting) and 40 sheep mandibles (only extracoronal splinting) were used for the in vitro part. The specimens were subjected to SBS at their incisoproximal contact, and debonding forces were measured with a universal testing machine (1 mm/min crosshead speed). Failure sites were examined under a stereomicroscope (×40 magnification). The SBS data were assessed via analysis of variance (ANOVA) and Tukey’s tests. The survival rate was significantly affected by the splint type (RB:95.3%, Kerr:91.6%, MFL:93.5%, Control:52.5%). No statistically significant differences were found between RB, Kerr, and MFL (p > 0.05) at all in vitro parts. Intracoronal splinting showed lower SBS values than extracoronal (p < 0.05). Lower SBS values were obtained in sheep teeth than human teeth (p < 0.05). Significantly different fracture patterns were noted between groups (p < 0.05). Only resin composite application seems to be inadequate for periodontal splinting. MFL splints are also economic and quite resistant, and they might be used as an alternative to fiber-reinforced composites.
Anahtar Kelimeler (Scopus)
shear bond strength clinical follow-up fracture Periodontal splint
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2016 yılı verileri
Journal of Adhesion Science and Technology
Q2
SJR Quartile
0,372
SJR Skoru
86
H-Index
Kategoriler: Chemistry (miscellaneous) (Q2) · Materials Chemistry (Q2) · Mechanics of Materials (Q3) · Surfaces and Interfaces (Q3) · Surfaces, Coatings and Films (Q3)
Alanlar: Chemistry · Engineering · Materials Science · Physics and Astronomy
Ülke: United Kingdom · Taylor and Francis Ltd.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

shear bond strength clinical follow-up fracture Periodontal splint

Makale Bilgileri

Dergi Journal of Adhesion Science and Technology
ISSN 0169-4243
Yıl 2016 / 11. ay
Cilt / Sayı 31 / 12
Sayfalar 1374 – 1385
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q3
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 4 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı- DİŞ HEKİMLİĞİ

YÖKSİS Yazar Kaydı

Yazar Adı KARABEKİROĞLU SAİD,ÖNCÜ ELİF,GÜRSES MERVE,ÜNLÜ NİMET
YÖKSİS ID 2234977