CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Residual monomer release from orthodontic adhesives cured with different light sources
Journal of Adhesion Science and Technology 2016 Cilt 30 Sayı 12
Scopus Eşleşmesi Bulundu
5
Atıf
30
Cilt
1354-1363
Sayfa
Scopus Yazarları: Murat Selim Botsali, Ozlem Akinci Sozer, Mustafa Altunsoy, Abdullah Demir, H. E. Ülker
Özet
Introduction: The aim of this study was to evaluate the residual monomer release from orthodontic adhesives cured with light-emitting diode (LED) and halogen light sources.Methods: Seven hundred and twenty stainless steel brackets were divided into 3 groups according to the adhesive system used (Transbond XT light-cure adhesive [TXT], Transbond LR capsule [LR], and Light Bond light-cure adhesive paste [LB]), and each group was divided into 2 subgroups according to light-curing procedure (LED or halogen). Brackets were bonded with adhesives onto tooth buccal surfaces and polymerized. Each specimen contained 24 brackets that simulated the oral environment (n = 5). The specimens were immersed in a 75% ethanol/water solution at 37 °C for 10 min, 1 h, 1 d, 7 d, 14 d, and 30 d, respectively. Eluted monomers (Bis-GMA, UDMA, and TEGDMA) were detected using HPLC.Results: There was residual monomer release at all time periods, and the highest amount of release was observed cumulatively on the 30th day. The cumulative Bis-GMA released from adhesives was not different (p > 0.05). The cumulative TEGDMA released from adhesives was statistically different (p < 0.05). There was no statistical difference between QTH and LED light-curing units for each adhesive (p > 0.05).Conclusions: The release of residual monomers stays at a high level for a long time after polymerization. The total leaching of residual monomers from the Light Bond light-cure sealant resin plus Light Bond light-cure adhesive paste was higher than that of other materials for both curing units. Different curing units (LED or QTH) did not affect the monomer release from the orthodontic adhesives.
Anahtar Kelimeler (Scopus)
TEGDMA UDMA Bis-GMA HPLC orthodontic adhesives residual monomer
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2016 yılı verileri
Journal of Adhesion Science and Technology
Q2
SJR Quartile
0,372
SJR Skoru
86
H-Index
Kategoriler: Chemistry (miscellaneous) (Q2) · Materials Chemistry (Q2) · Mechanics of Materials (Q3) · Surfaces and Interfaces (Q3) · Surfaces, Coatings and Films (Q3)
Alanlar: Chemistry · Engineering · Materials Science · Physics and Astronomy
Ülke: United Kingdom · Taylor and Francis Ltd.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

TEGDMA UDMA Bis-GMA HPLC orthodontic adhesives residual monomer

Makale Bilgileri

Dergi Journal of Adhesion Science and Technology
ISSN 0169-4243
Yıl 2016 / 2. ay
Cilt / Sayı 30 / 12
Sayfalar 1354 – 1363
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
TEŞV Puanı 18,00
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 5 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı- Çocuk Diş Hekimliği

YÖKSİS Yazar Kaydı

Yazar Adı BOTSALI MURAT SELİM,AKINCI SÖZER ÖZLEM,ALTUNSOY MUSTAFA,DEMİR ABDULLAH,ÜLKER HAYRİYE ESRA
YÖKSİS ID 2216766

Metrikler

Scopus Atıf 5
TEŞV Puanı 18,00
Yazar Sayısı 5