Scopus Eşleşmesi Bulundu
86
Atıf
17
Cilt
379-387
Sayfa
🔓
Açık Erişim
Scopus Yazarları: Kadri Murat Gurses, Muhammed Ulvi Yalçın, Duygu Kocyigit, Muhammet Dural, Banu Evranos, Hikmet Yorgun, Ahmet Hakan Ateş, Mehmet Levent Şahiner, Ergün Barış Kaya, Mehmet Ali Oto, Kudret Aytemir
Özet
Aims The second-generation cryoballoon (Arctic Front Advance™) (Arc-Adv-CB) has a redesigned injection system which distributes the refrigerant homogenously to the frontal balloon surface. The aim of this study was to compare the efficacy and safety of the Arc-Adv-CB and its predecessor (Arctic Front™) (Arc-CB) in patients who underwent pulmonary vein isolation (PVI) for atrial fibrillation (AF). Methods and results Three hundred and six patients (55.35 ± 10.60 years, 47.05% male) were included in the study. A total of 1205 pulmonary veins were attempted for PVI with either Arc-CB or Arc-Adv-CB. The follow-up durations were 30 (23-38) and 10 (8-13) months in Arc-CB and Arc-Adv-CB groups, respectively (P < 0.001). When the blanking period was considered, freedom from AF after a single ablation procedure was 68.53 and 90.83% in patients undergoing PVI with Arc-CB and Arc-Adv-CB, respectively. The most frequent complication was transient phrenic nerve palsy (PNP) which occurred in five(2.54%) and nine(8.26%) of patients undergoing PVI with Arc-CB and Arc-Adv-CB, respectively (P = 0.040). Left atrial (LA) diameter (hazard ratio, HR: 3.552, 95% CI: 2.034-6.201, P < 0.001), smoking history (HR:1.643, 95% CI: 1.011-2.671, P = 0.045), persistent AF (HR:1.725, 95% CI: 1.021-2.915, P = 0.041), duration of AF (HR:1.039, 95% CI: 1.000-1.080, P = 0.047), and early AF recurrence (HR:2.399, 95% CI: 1.443-3.989, P < 0.001) were associated with increased late AF recurrence. On the other hand, intraprocedural vagal reactions (HR: 0.550, 95% CI: 0.331-0.915, P = 0.021) and Arc-Adv-CB use (HR: 0.441, 95% CI: 0.225-0.866, P = 0.017) were associated with lower late AF recurrence. Left atrial diameter (HR: 3.072, 95% CI: 1.646-5.732, P < 0.001), early AF recurrence (HR: 1.906, 95% CI: 1.103-3.291, P = 0.021), and Arc-Adv-CB use (HR: 0.472, 95% CI: 0.239-0.931, P = 0.030) were independent predictors for late AF recurrence. Conclusion Our study has shown that Arc-Adv-CB use is associated with lower late AF recurrences at the cost of an increased risk for PNP.
Anahtar Kelimeler (Scopus)
Cryoballoon
Efficacy
Safety
Ablation
Atrial fibrillation
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2015 yılı verileri
Europace
Q1
SJR Quartile
2,412
SJR Skoru
137
H-Index
Kategoriler: Cardiology and Cardiovascular Medicine (Q1) · Physiology (medical) (Q1)
Alanlar: Medicine
Ülke: United Kingdom
· Oxford University Press
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
Cryoballoon
Efficacy
Safety
Ablation
Atrial fibrillation
Makale Bilgileri
Dergi
Europace
ISSN
1099-5129
Yıl
2015
/ 2. ay
Cilt / Sayı
17
/ 3
Sayfalar
379 – 387
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
YÖKSİS Atıf
26
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
11 kişi
Erişim Türü
Elektronik
Erişim Linki
Makaleye Git
Alan
Sağlık Bilimleri Temel Alanı-
Kardiyoloji
YÖKSİS Yazar Kaydı
Yazar Adı
AYTEMİR KUDRET,GÜRSES KADRİ MURAT,YALÇIN MUHAMMET ULVİ,KOÇYİĞİT DUYGU,DURAL MUHAMMET,EVRANOS BANU,YORGUN HİKMET,ATEŞ AHMET HAKAN,ŞAHİNER MEHMET LEVENT,KAYA ERGÜN BARIŞ,OTO MEHMET ALİ
YÖKSİS ID
1662814
Hızlı Erişim
Metrikler
YÖKSİS Atıf
26
Scopus Atıf
86
Yazar Sayısı
11