Scopus Eşleşmesi Bulundu
14
Atıf
26
Cilt
615-621
Sayfa
Scopus Yazarları: Muhammed Ulvi Yalçın, Kadri Murat Gurses, Duygu Kocyigit, Banu Evranos, Hikmet Yorgun, Levent Sahiner, Ergün Barış Kaya, Mehmet Ali Oto, Sacit A. Kesikli, Muhammet Dural, Dicle Guc, Kudret Aytemir, Necla Ozer
Özet
Cardiac Autoantibodies and AF Recurrence Introduction Recent evidence has suggested that autoantibodies may play an important role in the development of atrial fibrillation (AF). The predictive value of preprocedural autoantibodies against beta-1 adrenergic receptor (anti-β1-R) and M2-muscarinic acetylcholine receptor (anti-M2-R) for AF recurrence following cryoballoon-based pulmonary vein isolation (PVI) is still unclear. We aimed to determine the predictive value of preprocedural anti-β1-R and anti-M2-R levels for AF recurrence. Methods Eighty patients (mean age 54.25 ± 7.70 years; 40% female) with paroxysmal AF and preserved left ventricular function who underwent cryoballoon-based PVI were included in the study. Preprocedural anti-M2-R and anti-β1-R levels were measured with ELISA. Results At 1-year follow-up after ablation, late AF recurrence was observed in 17 (21.25%) patients. In the Cox regression model, including number of antiarrhythmic drugs, early AF recurrence, anti-β1-R levels >159.88 ng/mL, anti-M2-R levels >277.65 ng/mL, AF duration, and left atrial volume index, only anti-β1-R levels >159.88 ng/mL (HR: 4.281, P = 0.039) and anti-M2-R levels >277.65 ng/mL (HR: 4.313, P = 0.030) were found to be independent predictors of late AF recurrence. Anti-β1-R level >159.88 ng/mL was shown to predict late AF recurrence with a sensitivity of 70.59% and specificity of 90.48%. A cut-off value of 277.65 ng/mL for anti-M2-R level predicted AF recurrence with a sensitivity of 70.59% and specificity of 95.24%. Conclusion Preprocedural serum anti-β1-R and anti-M2-R levels are independent predictors of late AF recurrence following cryoballoon-based PVI in paroxysmal AF patients. Detection of preprocedural anti-β1-R and anti-M2-R levels may serve as a novel method for determination of paroxysmal AF patients who may not benefit from cryoballoon-based PVI.
Anahtar Kelimeler (Scopus)
catheter ablation
cryoballoon
recurrence
pulmonary vein isolation
atrial fibrillation
cardiac autoantibodies
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2015 yılı verileri
Journal of Cardiovascular Electrophysiology
Q1
SJR Quartile
2,000
SJR Skoru
154
H-Index
Kategoriler: Cardiology and Cardiovascular Medicine (Q1) · Physiology (medical) (Q1)
Alanlar: Medicine
Ülke: United States
· John Wiley and Sons Inc
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
catheter ablation
cryoballoon
recurrence
pulmonary vein isolation
atrial fibrillation
cardiac autoantibodies
Makale Bilgileri
Dergi
Journal of Cardiovascular Electrophysiology
ISSN
10453873
Yıl
2015
/ 6. ay
Cilt / Sayı
26
/ 6
Sayfalar
615 – 621
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI
YÖKSİS Atıf
1
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
13 kişi
Erişim Türü
Elektronik
Erişim Linki
Makaleye Git
Alan
Sağlık Bilimleri Temel Alanı-
Kardiyoloji
YÖKSİS Yazar Kaydı
Yazar Adı
YALÇIN MUHAMMET ULVİ,GÜRSES KADRİ MURAT,KOÇYİĞİT DUYGU,KESİKLİ SACİT ALTUĞ,DURAL MUHAMMET,EVRANOS BANU,YORGUN HİKMET,ŞAHİNER MEHMET LEVENT,KAYA ERGÜN BARIŞ,OTO MEHMET ALİ,GÜÇ DİCLE,AYTEMİR KUDRET,ÖZER NECLA
YÖKSİS ID
1662267
Hızlı Erişim
Metrikler
YÖKSİS Atıf
1
Scopus Atıf
14
Yazar Sayısı
13